Yayın:
Simultaneous Determination of Phorate and Oxyfluorfen in Well Water Samples with High Accuracy by GC-MS After Binary Dispersive Liquid-Liquid Microextraction

dc.contributor.authorAlkan, Emel
dc.contributor.authorKapukiran, Fatih
dc.contributor.authorEr, Elif Ozturk
dc.contributor.authorChormey, Dotse Selali
dc.contributor.authorKeyf, Seyfullah
dc.contributor.authorOzdogan, Nizamettin
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T14:14:50Z
dc.date.issued2018
dc.description.abstractThe potential risk of pesticides to cause harm to humans and other organisms even at trace levels calls for sensitive and accurate analytical techniques for their simultaneous qualitative and quantitative determinations. In this study, a sensitive binary dispersive liquid-liquid microextraction (B-DLLME) strategy was developed for the simultaneous determination of phorate and oxyfluorfen by gas chromatography mass spectrometry after extraction/preconcentration from aqueous solution. An experimental design was used to optimize parameters of the B-DLLME method to obtain maximum outcome. Under the optimum conditions of B-DLLME, the limit of detection (LOD) for phorate and oxyfluorfen were found to be 0.41 mu g L-1 and 0.54 mu g L-1, respectively. The detection limits correlate to about 37 and 73 folds enhancement in detection powers when compared to direct GC-MS determination of phorate and oxyfluorfen, respectively. In order to find out the applicability of developed method to real samples, recovery tests were performed for 20 mu g L-1 of phorate and oxyfluorfen spiked in well water samples. Percent recovery values were found to be 94.5% for phorate and 101.9% for oxyfluorfen.en
dc.description.urihttps://doi.org/10.1007/s11270-018-3939-2
dc.identifier.doi10.1007/s11270-018-3939-2
dc.identifier.eissn1573-2932
dc.identifier.issn0049-6979
dc.identifier.issue9
dc.identifier.urihttps://hdl.handle.net/20.500.14981/58408
dc.identifier.volume229
dc.identifier.wos000442020200003
dc.language.isoeng
dc.publisherSPRINGER INTERNATIONAL PUBLISHING AG
dc.relation.ispartofWATER AIR AND SOIL POLLUTION
dc.rightsopenAccess
dc.subjectPesticides
dc.subjectPhorate
dc.subjectOxyfluorfen
dc.subjectGC-MS
dc.subjectDLLME
dc.subjectB-DLLME
dc.subjectCHROMATOGRAPHY-MASS-SPECTROMETRY
dc.subjectFLAME PHOTOMETRIC DETECTION
dc.subjectNITROGEN-PHOSPHORUS DETECTION
dc.subjectSINGLE-DROP MICROEXTRACTION
dc.subjectSOLID-PHASE EXTRACTION
dc.subjectGAS-CHROMATOGRAPHY
dc.subjectORGANOPHOSPHORUS PESTICIDES
dc.subjectMULTIRESIDUE METHOD
dc.subjectHEALTH
dc.subjectRESIDUES
dc.subjectEnvironmental Sciences & Ecology
dc.subjectMeteorology & Atmospheric Sciences
dc.subjectWater Resources
dc.titleSimultaneous Determination of Phorate and Oxyfluorfen in Well Water Samples with High Accuracy by GC-MS After Binary Dispersive Liquid-Liquid Microextraction
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar