Yayın:
Comparative photo electro catalytic oxidation of real pharmaceutical wastewater using Ag/TiO2: Process optimization and acute toxicity removal

dc.contributor.authorAtes, Ayse Elif
dc.contributor.authorAtes, Sinan
dc.contributor.authorAydin, Serdar
dc.contributor.authorVarank, Gamze
dc.date.accessioned2026-06-27T15:21:19Z
dc.date.issued2025
dc.description.abstractPharmaceutical wastewater contains persistent organic pollutants and bioactive compounds that pose significant environmental risks. Despite extensive studies on photocatalytic degradation, research on real pharmaceutical wastewater remains limited. This study evaluates the performance of silver-doped titanium dioxide (Ag/TiO2) in real pharmaceutical wastewater treatment through photo electro catalytic oxidation (PECO) and electro catalytic oxidation (ECO), with a focus on process optimization, pollutant removal efficiency, and ecotoxicological impacts, and the comparative performance of Ag/TiO2 as both anode and cathode materials. A Central Composite Design (CCD) approach was employed to systematically analyze the effects of pH, reaction time, current density, and temperature on chemical oxygen demand (COD) and UV254 removal efficiencies. Response Surface Methodology (RSM)-based correlation models accurately predicted Results with 98 % reliability. Under optimized conditions, PECO demonstrated its high efficiency in wastewater treatment by achieving 76 % COD and 86 % UV254 removal. Unlike similar studies in literature, which often ignore the synergistic effects of resistant pollutants, this study provides a comprehensive and realistic ecotoxicological assessment. Acute toxicity tests using Daphnia magna revealed that untreated wastewater caused 97 % immobilization, while PECO reduced it to 23 % without dilution in 30 min, highlighting its superior detoxification potential.en
dc.description.sponsorshipScientific Research Projects Coordination Unit of Istanbul University-Cerrahpasa [FDK-2023-37294]
dc.description.urihttps://doi.org/10.1016/j.jwpe.2025.108109
dc.identifier.doi10.1016/j.jwpe.2025.108109
dc.identifier.issn2214-7144
dc.identifier.urihttps://hdl.handle.net/20.500.14981/70109
dc.identifier.volume76
dc.identifier.wos001511994200003
dc.language.isoeng
dc.publisherELSEVIER
dc.relation.ispartofJOURNAL OF WATER PROCESS ENGINEERING
dc.subjectPhoto electro catalysis
dc.subjectReal pharmaceutical wastewater
dc.subjectEcotoxicity
dc.subjectProcess optimization
dc.subjectAg/TiO2
dc.subjectULTRASOUND-ASSISTED EXTRACTION
dc.subjectPHOTOCATALYTIC DEGRADATION
dc.subjectDOPED TIO2
dc.subjectORGANIC POLLUTANTS
dc.subjectMESOPOROUS TIO2
dc.subjectDYES
dc.subjectUV
dc.subjectEngineering
dc.subjectWater Resources
dc.titleComparative photo electro catalytic oxidation of real pharmaceutical wastewater using Ag/TiO2: Process optimization and acute toxicity removal
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar