Yayın:
Evaluation of Installation Quality on Polyethelene Pipe Performance under Surcharge Loads

dc.contributor.authorTerzi, Niyazi U.
dc.contributor.authorDusunceli, Necmi
dc.contributor.authorYilmazturk, Ferruh
dc.contributor.authorYildirim, S.
dc.date.accessioned2026-06-27T12:52:05Z
dc.date.issued2010
dc.description.abstractIn this study, a comprehensive laboratory test on 100 mm diameter HDPE 100 polyethylene flexible pipe buried in quartz sand is described. The laboratory test was performed in a 40 mm thick plexiglass-fronted test tank which replicated a classical trench section in field conditions. The polyethylene flexible pipe was positioned against the glass with its longitudinal axis perpendicular to the glass. This allowed direct observation of the backfill-pipe interactions and pipe performance under surcharge loads. Three high definition photogrammetric cameras were taken photogrammetric images through the glass allowing the discrete measurement and image processing of the deformation patterns of the polyethelene pipe conduit during the pipe installation and incremental surcharge loading. Vertical loads were applied in increments of 10 kPa to 150 kPa using air pressure membranes. According to the test results, it is understood that the installation technique and backfill properties have an important effect on circumferential strains, performance and deformation characteristics of polyethelene HDPE pipe. It was also observed that close-range image processing is a very simple and appropriate method for measuring three dimensional pipe deformations under various conditions.en
dc.description.urihttps://doi.org/10.1063/1.3455663
dc.identifier.doi10.1063/1.3455663
dc.identifier.endpage+
dc.identifier.isbn978-0-7354-0804-3
dc.identifier.issn0094-243X
dc.identifier.startpage55
dc.identifier.urihttps://hdl.handle.net/20.500.14981/47634
dc.identifier.volume1255
dc.identifier.wos000283528400019
dc.language.isoeng
dc.publisherAMER INST PHYSICS
dc.relation.conference5th International Conference on Times of Polymers (TOP) and Composites
dc.relation.ispartof5TH INTERNATIONAL CONFERENCE ON TIMES OF POLYMERS TOP AND COMPOSITES
dc.subjectHDPE flexible pipe
dc.subjectSoil-Pipe Interaction
dc.subjectPhysics
dc.subjectPolymer Science
dc.titleEvaluation of Installation Quality on Polyethelene Pipe Performance under Surcharge Loads