Yayın:
Conceptual Design and Sensitivity Analysis of MRI Magnets From REBCO HTS Tapes

dc.contributor.authorBoran, Yakup
dc.contributor.authorKara, Husnu
dc.contributor.authorInanir, Fedai
dc.contributor.authorYildiz, Sukru
dc.date.accessioned2026-06-27T14:42:50Z
dc.date.issued2022
dc.description.abstractAn actively shielded wide-bore magnet system has been designed for magnetic resonance imaging. The gradient-based optimization solver of COMSOL Multiphysics has been used to obtain an optimum geometrical arrangement of symmetrical electromagnets in the magnetic resonance imaging (MRI) system. To generate a high and homogeneous magnetic field, we employed a second-generation rare-earth barium-copper-oxide (REBCO) high-temperature superconductor (HTS), which was wound into 10 double pancake coils (DPC). The dimensions of the DPC sets have been chosen considering the size of REBCO HTS tapes, and the optimized design solution provides magnetic field, stray field, and current passing through the HTS tapes on each DPC set. The design details of a 1.5 T actively shielded magnet as well as the sensitivity analysis of the inhomogeneity, stray field, and currents with respect to coil positions have been presented. Optimum parameters for various designs are listed. The inhomogeneity of 1.23 ppm in the 200 mm diameter of spherical volume (DSV) and a stray field of as low as 0.05 G outside of the 5 m distance were achieved. Additionally, a low peak field of 2.40 T in DPC sets has been accomplished.en
dc.description.urihttps://doi.org/10.1109/tasc.2022.3200575
dc.identifier.doi10.1109/tasc.2022.3200575
dc.identifier.eissn1558-2515
dc.identifier.issn1051-8223
dc.identifier.issue8
dc.identifier.urihttps://hdl.handle.net/20.500.14981/63838
dc.identifier.volume32
dc.identifier.wos000848211900001
dc.language.isoeng
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
dc.relation.ispartofIEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY
dc.rightsopenAccess
dc.subjectMagnetic resonance imaging
dc.subjectSuperconducting magnets
dc.subjectMagnetic shielding
dc.subjectMagnetic noise
dc.subjectMagnetic fields
dc.subjectHigh-temperature superconductors
dc.subjectMagnetic flux
dc.subjectCOMSOL
dc.subjectdouble pancake coil
dc.subjecthigh temperature superconductor
dc.subjectEngineering
dc.subjectPhysics
dc.titleConceptual Design and Sensitivity Analysis of MRI Magnets From REBCO HTS Tapes