Yayın:
Furoic acid-doped-over-oxidized poly (3, 4-ethylenedioxythiophene)-based electrochemical sensor for selective, sensitive and concurrent quantification of paracetamol, codeine phosphate and caffeine in pharmaceutical formulation

dc.contributor.authorKocyigit, Nilufer
dc.contributor.authorDinc-Zor, Sule
dc.contributor.authorYagci, Ozlem
dc.contributor.authorArvas, Melih Besir
dc.date.accessioned2026-06-27T15:14:31Z
dc.date.issued2025
dc.description.abstractHerein, furoic acid-doped-over-oxidized poly(3,4-ethylenedioxythiophene)-modified pencil graphite electrode (furoic acid-doped-oo-PEDOT/PGE) was firstly prepared and then employed for the simultaneous and sensitive electrochemical determination of paracetamol (PAR), codeine phosphate (COD-P) and caffeine (CAF). Distinctive functional properties of the furoic acid-doped-oo-PEDOT electrode exhibit selective, sensitive and rapid analysis of the target drugs. The electrochemical performance of the prepared sensor electrode was investigated using differential pulse voltammetry (DPV), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) methods. The calibration curves of the drugs show excellent linearity over a concentration ranges: 0.5-100 mu mol L-1 for PAR, 0.75-100 mu mol L-1 for COD-P and 25-5000 mu mol L-1 for CAF and limit of detection (LOD) values of 0.075, 0.36 and 9.41 mu mol L-1for the analytes, respectively. Finally, the fabricated sensor was successively used for the simultaneous determination of PAR, COD-P, and CAF in commercial pharmaceutical samples and displayed appreciable recoveries.Graphical abstractElectrochemical Sensor Design for Paracetamol, Codeine phosphate and Caffeineen
dc.description.urihttps://doi.org/10.1557/s43578-024-01513-3
dc.identifier.doi10.1557/s43578-024-01513-3
dc.identifier.eissn2044-5326
dc.identifier.endpage526
dc.identifier.issn0884-2914
dc.identifier.issue4
dc.identifier.startpage509
dc.identifier.urihttps://hdl.handle.net/20.500.14981/69377
dc.identifier.volume40
dc.identifier.wos001399431800001
dc.language.isoeng
dc.publisherSPRINGER HEIDELBERG
dc.relation.ispartofJOURNAL OF MATERIALS RESEARCH
dc.subjectElectrochemical sensor
dc.subjectOO-PEDOT
dc.subjectFuroic acid
dc.subjectParacetamol
dc.subjectCodeine phosphate
dc.subjectCaffeine
dc.subjectACETAMINOPHEN
dc.subjectOXIDE
dc.subjectMaterials Science
dc.titleFuroic acid-doped-over-oxidized poly (3, 4-ethylenedioxythiophene)-based electrochemical sensor for selective, sensitive and concurrent quantification of paracetamol, codeine phosphate and caffeine in pharmaceutical formulation
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar