Determination of lead at trace levels in mussel and sea water samples using vortex assisted dispersive liquid-liquid microextraction-slotted quartz tube-flame atomic absorption spectrometry

dc.contributor.authorErarpat, Sezin
dc.contributor.authorOzzeybek, Gozde
dc.contributor.authorChormey, Dotse Selali
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T14:05:31Z
dc.date.issued2017
dc.description.abstractIn this study, dispersive liquid-liquid microextraction (DLLME) and slotted quartz tube (SQT) were coupled to flame atomic absorption spectrometry (FAAS) to increase the sensitivity of lead. Conditions such as the formation of the lead-dithizone complex, efficiency of the DLLME method and the output of the SQT were systematically optimized to improve the detection limit for the analyte. The conventional FAAS system was improved upon by about 3.0 times with SQT-FAAS, 32 times with DLLME-FAAS and 142 times with DLLME-SQT-FAAS. The method was applicable over a wide linear range (10-500 mu g L-1). The limit of detection (LOD) determined by DLLME-SQT-FAAS for seawater and mussel were 2.7 mu g L-1 and 270 mu g kg(-1), respectively. The percent recoveries obtained for mussel and seawater samples (spiked at 20 and 50 mu g L-1) were 95-96% and 98-110%, respectively. (C) 2017 Elsevier Ltd. All rights reserved.en
dc.description.urihttps://doi.org/10.1016/j.chemosphere.2017.09.072
dc.identifier.doi10.1016/j.chemosphere.2017.09.072
dc.identifier.eissn1879-1298
dc.identifier.endpage185
dc.identifier.issn0045-6535
dc.identifier.pubmed28938199
dc.identifier.startpage180
dc.identifier.urihttps://hdl.handle.net/20.500.14981/56887
dc.identifier.volume189
dc.identifier.wos000414817900020
dc.language.isoeng
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD
dc.relation.ispartofCHEMOSPHERE
dc.subjectLead
dc.subjectDispersive liquid-liquid microextraction
dc.subjectSlotted quartz tube
dc.subjectFlame atomic absorption spectrometry
dc.subjectSeawater
dc.subjectBiotissues
dc.subjectDELTA-AMINOLEVULINIC-ACID
dc.subjectONLINE PRECONCENTRATION
dc.subjectVAPOR GENERATION
dc.subjectWASTE-WATER
dc.subjectCADMIUM
dc.subjectCOPPER
dc.subjectEXTRACTION
dc.subjectSCHIZOPHRENIA
dc.subjectPERFORMANCE
dc.subjectEnvironmental Sciences & Ecology
dc.titleDetermination of lead at trace levels in mussel and sea water samples using vortex assisted dispersive liquid-liquid microextraction-slotted quartz tube-flame atomic absorption spectrometry
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar