Yayın:
Parallel operation characteristics of PEM fuel cell and microturbine power plants

Yükleniyor...
Küçük Resim

Tarih

Kurum Yazarları

Danışman

item.page.editor

Editör

Bölüm / Program

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

ELSEVIER SCIENCE BV

DOI

10.1016/j.jpowsour.2007.03.038

Türü

View PlumX Details

Araştırma Projeleri

Akademik Birimler

Dergi Sayısı

Özet

This paper reports on the dynamic behavior of a 250 kW proton exchange membrane fuel cell power plant (PEM FCPP) and a 250 kW microturbine (MT) when operating in parallel. A load sharing control scheme is used to distribute the load equally between the PEM FCPP and the MT. For stand alone operation of a PEM FCPP, a set of batteries or ultracapacitors are needed in order to satisfy the power mismatch during transient periods. Using MT in parallel with the PEM FCPP helps in eliminating the need for storage devices. Models for the PEM FCPP and the MT with power, voltage and speed controls are used to determine the dynamic response of the system to a step change in the load. Simulation results indicate viability of parallel operation of the PEM FCPP and the MT. These results are obtained using MATLAB (R), Simulink (R), and SimpowerSystems (R). (C) 2007 Elsevier B.V. All rights reserved.

Tanım

Dergi veya Seri

JOURNAL OF POWER SOURCES

ISSN

0378-7753

ISBN

Haklar

Alıntı

Koleksiyonlar

Onay

Gözden geçir

Tamamlayıcı Bilgiler

Referans Gösteren

Related Patent

Related Goal

0

Views

0

Downloads