Yayın:
Influence of Plastic Deformation and Hydroxyapatite Coating on Structure, Mechanical, Corrosion, Antibacterial and Cell Viability Properties of Zinc Based Biodegradable Alloys

dc.contributor.authorAksakal, B.
dc.contributor.authorIsin, Ege
dc.contributor.authorAslan, N.
dc.contributor.authorCihangir, S.
dc.contributor.authorSezek, S.
dc.date.accessioned2026-06-27T15:07:10Z
dc.date.issued2024
dc.description.abstractZinc (Zn)-based biodegradable alloys have been at the forefront of absorbable biomaterial research in recent years due to their high biocompatibility and corrosion rates. The arc melting process was used to produce the Zn-1Cu-1Ag biodegradable alloy. The influence of different plastic deformation rates on the microstructure of the material was examined after the cold rolling at deformation rates of 47% and 61%. The undeformed and deformed alloys have been hydroxyapatite-coated using the electrophoretic deposition process to improve its surface, corrosion, and bioactivity properties. Optical, XRD, SEM, and EDS examinations were used to analyze the samples' uncoated, coated, and rolled-unrolled forms. The nucleation of the (Ag, Cu)Zn4 secondary phase was formed during the rolling process. Hardness and compression tests were used to determine the mechanical properties of cast and rolled alloys, and in vitro corrosion tests were carried out in simulated body fluid. Antimicrobial and cell viability tests are executed to demonstrate the biocompatibility of the deformed and HA-coated Zn-1Cu-1Ag alloy. The mechanical properties were improved after the rolling process, with the highest results found in 47% of the rolled samples exhibiting a compressive strength of 412.65 +/- 0.5 MPa and 61% of the rolled samples exhibiting a hardness value of 88.1 +/- 0.5 HV. The samples that were rolled (61%) and coated with hydroxyapatite (HA) exhibited the highest level of corrosion resistance. The antimicrobial tests revealed that the rolled and HA coated Zn1Cu1Ag groups exhibited greater inhibition rates (47 and 61%) compared to the other groups when tested against E. coli. The HA-coated groups exhibited good cell viability ratios, with the maximum viability seen in the rolled and HA-coated group at 47%.en
dc.description.sponsorshipFimath
dc.description.sponsorshiprat University
dc.description.urihttps://doi.org/10.1007/s12540-024-01710-z
dc.identifier.doi10.1007/s12540-024-01710-z
dc.identifier.eissn2005-4149
dc.identifier.endpage3337
dc.identifier.issn1598-9623
dc.identifier.issue12
dc.identifier.startpage3320
dc.identifier.urihttps://hdl.handle.net/20.500.14981/68161
dc.identifier.volume30
dc.identifier.wos001232180100001
dc.language.isoeng
dc.publisherKOREAN INST METALS MATERIALS
dc.relation.ispartofMETALS AND MATERIALS INTERNATIONAL
dc.rightsopenAccess
dc.subjectBiodegradable metals
dc.subjectZn-1Cu1Ag
dc.subjectRolling
dc.subjectEPD coating
dc.subjectCorrosion
dc.subjectCell viability
dc.subjectIN-VITRO DEGRADATION
dc.subjectSILVER NANOPARTICLES
dc.subjectDESIGN
dc.subjectMICROSTRUCTURE
dc.subjectTITANIUM
dc.subjectMaterials Science
dc.subjectMetallurgy & Metallurgical Engineering
dc.titleInfluence of Plastic Deformation and Hydroxyapatite Coating on Structure, Mechanical, Corrosion, Antibacterial and Cell Viability Properties of Zinc Based Biodegradable Alloys