Yayın:
Electro-activated peroxymonosulfate and peroxydisulfate oxidation of leachate nanofiltration concentrate: multiple-response optimization

dc.contributor.authorVarank, G.
dc.contributor.authorYazici Guvenc, S.
dc.contributor.authorDemir, A.
dc.date.accessioned2026-06-27T14:28:41Z
dc.date.issued2020
dc.description.abstractIn this study, the performance of electro-peroxymonosulfate and electro-peroxydisulfate methods in biologically stabilized leachate nanofiltration concentrate treatment was investigated. To increase treatability and biodegradability of the concentrated leachate was aimed. Central composite design was applied for the optimization of process parameters and development of mathematical model. Variance analyses were performed to attain the interaction among the responses and process variables and to analyze the data. Second-order regression models were developed by Statgraphics Centurion XVI.I software program in order to estimate the removal efficiencies. Model's correlation coefficients for COD removal through electro-peroxymonosulfate and electro-peroxydisulfate processes were determined to be 0.8769 and 0.8910, respectively, expressing conformity of the experimental data to the model. COD removal rates obtained through electro-peroxymonosulfate and electro-peroxydisulfate processes under optimum conditions (HSO5-/COD ratio: 2.5, current: 1.8 A, pH: 6.4 and reaction time: 35.9 min for electro-peroxymonosulfate process and S(2)O8-2/COD ratio: 1.9, current: 2.1 A, pH: 5.1 and reaction time: 32.3 min for electro-peroxydisulfate process) were determined as 84.2% and 79.6%, respectively. Before advanced treatment processes, the biodegradable COD fraction of leachate nanofiltration concentrate was 12.7% and the soluble COD fraction was 78.3%. After electro-peroxymonosulfate process, biodegradable COD fraction increased to the value of 44.6% and the soluble COD fraction increased to the value of 90.5%, whereas after electro-peroxydisulfate process, biodegradable COD fraction increased to the value of 37.5% and the soluble COD fraction increased to the value of 87.4%. The results of the study showed that electro-peroxymonosulfate and electro-peroxydisulfate oxidation processes were effective treatment methods for leachate concentrates with low biodegradability.en
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TUBITAK) [118Y278]
dc.description.urihttps://doi.org/10.1007/s13762-020-02651-x
dc.identifier.doi10.1007/s13762-020-02651-x
dc.identifier.eissn1735-2630
dc.identifier.endpage2720
dc.identifier.issn1735-1472
dc.identifier.issue5
dc.identifier.startpage2707
dc.identifier.urihttps://hdl.handle.net/20.500.14981/61061
dc.identifier.volume17
dc.identifier.wos000510362700001
dc.language.isoeng
dc.publisherSPRINGER
dc.relation.ispartofINTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY
dc.subjectActivated-sulfate radicals
dc.subjectAdvanced oxidation
dc.subjectCentral composite design
dc.subjectConcentrated leachate
dc.subjectCOD fractions
dc.subjectMATURE LANDFILL LEACHATE
dc.subjectPHENOLIC WASTE-WATER
dc.subjectSURFACE METHODOLOGY
dc.subjectFENTON OXIDATION
dc.subjectELECTROCOAGULATION PROCESS
dc.subjectREFRACTORY ORGANICS
dc.subjectAQUEOUS-SOLUTION
dc.subjectCOAGULATION
dc.subjectDEGRADATION
dc.subjectREMOVAL
dc.subjectEnvironmental Sciences & Ecology
dc.titleElectro-activated peroxymonosulfate and peroxydisulfate oxidation of leachate nanofiltration concentrate: multiple-response optimization
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar