Yayın:
An experimental study on the determination of a hermetic reciprocating compressor's discharge and suction losses

dc.contributor.authorBacak, Aykut
dc.contributor.authorPinarbasi, Ali
dc.contributor.authorDalkilic, Ahmet Selim
dc.date.accessioned2026-06-27T14:48:59Z
dc.date.issued2024
dc.description.abstractThe most popular approach to determine compressor losses is to generate compressor pressure-volume indication diagrams. The pressure-volume indication diagram of a novel hermetic reciprocating compressor for household refrigerators operating with R600a was experimentally obtained under American Society of Heating, Refrigerating and Air-Conditioning Engineers (54.4 degrees C/-23.3 degrees C) and additional specific working conditions of (40 degrees C/-25 degrees C), (25 degrees C/-20 degrees C) and (35 degrees C/-15 degrees C). Apart from most studies, experiments have been performed using a calorimeter. The alteration of suction and discharge pressures with crank angle of the investigated compressor was presented as both graphical and numerical information during condensation and evaporation, separately. As a result of the analyses, total compressor losses increased with decreasing the condensation pressure. These losses were 10%, 8.7%, 5.7% and 4.6% of the total work and they were observed at the same speed of 1300 rotation per minute (rpm) as the lowest one under all operating conditions. Besides, the suction line losses having the largest losses in the compressor were calculated as 50.1%, 50.9%, 64.9% and 67.9% of the total one, and it has been determined that they increased with increasing the condensation pressure. Due to the more complex design of the equipment in the suction line, the losses in this region were found to be higher than those in the discharge line, as expected.en
dc.description.urihttps://doi.org/10.1177/09544089231154350
dc.identifier.doi10.1177/09544089231154350
dc.identifier.eissn2041-3009
dc.identifier.endpage1344
dc.identifier.issn0954-4089
dc.identifier.issue3
dc.identifier.startpage1330
dc.identifier.urihttps://hdl.handle.net/20.500.14981/65123
dc.identifier.volume238
dc.identifier.wos000929457000001
dc.language.isoeng
dc.publisherSAGE PUBLICATIONS LTD
dc.relation.ispartofPROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING
dc.subjectHermetic reciprocating compressor
dc.subjectpV indicator diagram
dc.subjectdischarge losses
dc.subjectsuction losses
dc.subjectOPTIMIZATION
dc.subjectVALVE
dc.subjectEngineering
dc.titleAn experimental study on the determination of a hermetic reciprocating compressor's discharge and suction losses
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar