Yayın:
Determination of micropollutants in wastewater matrix using gas chromatography-mass spectrometry after optimization of dispersive liquid-liquid microextraction

dc.contributor.authorCaglak, A.
dc.contributor.authorChormey, D. S.
dc.contributor.authorEngin, G. Onkal
dc.contributor.authorBakirdere, S.
dc.date.accessioned2026-06-27T14:18:19Z
dc.date.issued2019
dc.description.abstractIn this study, an experimental design was used to optimize dispersive liquid-liquid microextraction for the extraction/preconcentration of micropollutants that have endocrine disruption potential, for the determination by gas chromatography-mass spectrometry. The analytes were selected from endocrine disrupting chemicals, such as pesticides, phthalates, hormones, alkyl phenols and pharmaceuticals. The most influential parameters of the extraction method determined in a pre-optimization step were included in the design model to determine their optimum amounts and to evaluate their interactions in a series of combinations. The design model predictor was used to obtain optimum experimental values, with which analytical performance of each analyte was determined with calibration plots. Deuterated bisphenol A (BPA D16) was added as an internal standard to all samples and calibration standards to improve the precision of the results. The limits of detection for analytes ranged between 0.10 and 16 mu g/L. The developed method was applied to synthetic and municipal wastewater samples, and the results obtained from spiked recovery tests ranged between 79 and 113%. These results confirmed the applicability of the method for the selected sample matrices. The complex nature of the samples tested in this study affected the recovery of analytes. However, matrix matching calibration was employed to overcome the matrix effects and this improved the recovery results.en
dc.description.sponsorshipYildiz Technical University [FDK-2017-3170]
dc.description.urihttps://doi.org/10.1007/s13762-019-02319-1
dc.identifier.doi10.1007/s13762-019-02319-1
dc.identifier.eissn1735-2630
dc.identifier.endpage7292
dc.identifier.issn1735-1472
dc.identifier.issue11
dc.identifier.startpage7285
dc.identifier.urihttps://hdl.handle.net/20.500.14981/59041
dc.identifier.volume16
dc.identifier.wos000489337200070
dc.language.isoeng
dc.publisherSPRINGER
dc.relation.ispartofINTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY
dc.subjectEndocrine disruptors
dc.subjectMicroextraction
dc.subjectPesticide
dc.subjectWastewater
dc.subjectPESTICIDES
dc.subjectGC
dc.subject2,4,6-TRICHLOROPHENOL
dc.subjectESTROGEN
dc.subjectFATE
dc.subjectEnvironmental Sciences & Ecology
dc.titleDetermination of micropollutants in wastewater matrix using gas chromatography-mass spectrometry after optimization of dispersive liquid-liquid microextraction
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar