Yayın:
Trace analysis of amines in cheese serum with liquid chromatographic potentiometric detection by using amine-selective electrode

dc.contributor.authorAydin, Rukiye
dc.contributor.authorAsan, Adem
dc.contributor.authorAttar, Azade
dc.contributor.authorIsildak, Ibrahim
dc.date.accessioned2026-06-27T14:29:31Z
dc.date.issued2019
dc.description.abstractA trace quantification liquid chromatographic-potentiometric method for the determination of amines in cheese serum is described. An all solid-state contact polyvinyl chloride membrane amine-selective electrode was prepared and used as a detector in a low-dead volume flow through detection cell. Potentiometric performance characteristics of the proposed electrodes were then examined. A slope of 52.4 +/- 3.8 mV per decade toward amines was received at the concentration range of 1.0 x 10(-2)-8.0 x 10(-6) M (r(2) = 0.99) under dynamic conditions. Six amine compounds were separated, with a good resolution in the chromatographic system by using acetonitrile-methane sulfonic acid mobile phase gradient at the flow-rate of 1 mL min(-1) in 30 min. The potentiometric detector was successfully applied to the analysis of amines in cheese serum samples. The relative standard deviations were ranged from 2.2% to 4.0% and recoveries were ranged from 88% to 101% for the determination. The average concentrations of ethylamine, butylamine and hexylamine in cheese serum samples calculated were 6.46, 4.51 and 8.37 mu g L-1 respectively. (C) 2016 The Authors. Production and hosting by Elsevier B.V. on behalf of King Saud University.en
dc.description.sponsorshipScience and Technology Research Council of Turkey (TUBITAK) [107T336]
dc.description.urihttps://doi.org/10.1016/j.arabjc.2016.07.006
dc.identifier.doi10.1016/j.arabjc.2016.07.006
dc.identifier.eissn1878-5379
dc.identifier.endpage4540
dc.identifier.issn1878-5352
dc.identifier.issue8
dc.identifier.startpage4533
dc.identifier.urihttps://hdl.handle.net/20.500.14981/61228
dc.identifier.volume12
dc.identifier.wos000504900300263
dc.language.isoeng
dc.publisherELSEVIER
dc.relation.ispartofARABIAN JOURNAL OF CHEMISTRY
dc.rightsopenAccess
dc.subjectAmine-selective electrodes
dc.subjectAmine analysis
dc.subjectPotentiometric detection
dc.subjectHigh performance liquid chromatography
dc.subjectBIOGENIC-AMINES
dc.subjectALIPHATIC-AMINES
dc.subjectDERIVATIZATION
dc.subjectDRUGS
dc.subjectChemistry
dc.titleTrace analysis of amines in cheese serum with liquid chromatographic potentiometric detection by using amine-selective electrode
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar