Yayın: Trace analysis of amines in cheese serum with liquid chromatographic potentiometric detection by using amine-selective electrode
| dc.contributor.author | Aydin, Rukiye | |
| dc.contributor.author | Asan, Adem | |
| dc.contributor.author | Attar, Azade | |
| dc.contributor.author | Isildak, Ibrahim | |
| dc.date.accessioned | 2026-06-27T14:29:31Z | |
| dc.date.issued | 2019 | |
| dc.description.abstract | A trace quantification liquid chromatographic-potentiometric method for the determination of amines in cheese serum is described. An all solid-state contact polyvinyl chloride membrane amine-selective electrode was prepared and used as a detector in a low-dead volume flow through detection cell. Potentiometric performance characteristics of the proposed electrodes were then examined. A slope of 52.4 +/- 3.8 mV per decade toward amines was received at the concentration range of 1.0 x 10(-2)-8.0 x 10(-6) M (r(2) = 0.99) under dynamic conditions. Six amine compounds were separated, with a good resolution in the chromatographic system by using acetonitrile-methane sulfonic acid mobile phase gradient at the flow-rate of 1 mL min(-1) in 30 min. The potentiometric detector was successfully applied to the analysis of amines in cheese serum samples. The relative standard deviations were ranged from 2.2% to 4.0% and recoveries were ranged from 88% to 101% for the determination. The average concentrations of ethylamine, butylamine and hexylamine in cheese serum samples calculated were 6.46, 4.51 and 8.37 mu g L-1 respectively. (C) 2016 The Authors. Production and hosting by Elsevier B.V. on behalf of King Saud University. | en |
| dc.description.sponsorship | Science and Technology Research Council of Turkey (TUBITAK) [107T336] | |
| dc.description.uri | https://doi.org/10.1016/j.arabjc.2016.07.006 | |
| dc.identifier.doi | 10.1016/j.arabjc.2016.07.006 | |
| dc.identifier.eissn | 1878-5379 | |
| dc.identifier.endpage | 4540 | |
| dc.identifier.issn | 1878-5352 | |
| dc.identifier.issue | 8 | |
| dc.identifier.startpage | 4533 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14981/61228 | |
| dc.identifier.volume | 12 | |
| dc.identifier.wos | 000504900300263 | |
| dc.language.iso | eng | |
| dc.publisher | ELSEVIER | |
| dc.relation.ispartof | ARABIAN JOURNAL OF CHEMISTRY | |
| dc.rights | openAccess | |
| dc.subject | Amine-selective electrodes | |
| dc.subject | Amine analysis | |
| dc.subject | Potentiometric detection | |
| dc.subject | High performance liquid chromatography | |
| dc.subject | BIOGENIC-AMINES | |
| dc.subject | ALIPHATIC-AMINES | |
| dc.subject | DERIVATIZATION | |
| dc.subject | DRUGS | |
| dc.subject | Chemistry | |
| dc.title | Trace analysis of amines in cheese serum with liquid chromatographic potentiometric detection by using amine-selective electrode | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| local.import.source | WOS |