Yayın:
Development and performance evaluation of a novel scintillation-based active shielding gamma probe

dc.contributor.authorKolcu, O. B.
dc.contributor.authorYetkin, T.
dc.contributor.authorZengin, A. T.
dc.contributor.authorIren, E.
dc.contributor.authorGunay, E. C.
dc.date.accessioned2026-06-27T15:01:10Z
dc.date.issued2024
dc.description.abstractThe gamma probe is a commonly used detector for localizing sentinel lymph nodes after the injection of radiopharmaceuticals. In recent years, studies have focused on improving the features of gamma probes to achieve more consistent localization of the radiotracer uptake. As part of this effort, a novel gamma probe prototype based on an active shielding was developed, and its characteristics, including sensitivity, resolution and shielding effectiveness, were determined. The prototype integrates trapezoidal-shaped bismuth germanate (BGO) array coupled with a silicon photomultiplier (SiPM) array, accompanied by dedicated electronics and software for stand alone usage. We conducted a thorough characterization, validating experimental observations through Monte Carlo simulations using the GEANT4 simulation package. In scattering environment, with a probe-source distance of 30 mm, the experimental results show that the detector sensitivity is 120 +/- 5\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$120\pm 5$$\end{document} cps/MBq, and the spatial and angular resolutions, in terms of full width at half maximum (FWHM), are 44.8 +/- 1.3\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$44.8\pm 1.3$$\end{document} mm and 87.3 +/- 1.5 degrees\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$87.3\pm 1.5 {\circ }$$\end{document}, respectively. The shielding effectiveness of the probe was determined to be greater than 95%\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\%$$\end{document}. The prototype with active shielding was found to have comparable performance to conventional gamma probes.en
dc.description.sponsorshipTrkiye Bilimsel ve Teknolojik Arastirma Kurumu
dc.description.urihttps://doi.org/10.1007/s13246-024-01474-1
dc.identifier.doi10.1007/s13246-024-01474-1
dc.identifier.eissn2662-4737
dc.identifier.endpage1612
dc.identifier.issn2662-4729
dc.identifier.issue4
dc.identifier.pubmed39133371
dc.identifier.startpage1603
dc.identifier.urihttps://hdl.handle.net/20.500.14981/67206
dc.identifier.volume47
dc.identifier.wos001295526200004
dc.language.isoeng
dc.publisherSPRINGER
dc.relation.ispartofPHYSICAL AND ENGINEERING SCIENCES IN MEDICINE
dc.subjectGamma probes
dc.subjectIntra-operative probes
dc.subjectActive shielding
dc.subjectSentinel lymph node
dc.subjectEngineering
dc.subjectRadiology, Nuclear Medicine & Medical Imaging
dc.titleDevelopment and performance evaluation of a novel scintillation-based active shielding gamma probe
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar