Yayın:
MUNICIPAL WASTEWATER TREATMENT WITH A PILOT SCALE TWO-STAGE CASCADE BIOLOGICAL NUTRIENT REMOVAL PROCESS

dc.contributor.authorManav Demir, Neslihan
dc.contributor.authorDebik, Eyup
dc.contributor.authorCoskun, Tamer
dc.contributor.institutionauthorMANAV DEMİR, Neslihan
dc.date.accessioned2026-06-27T13:54:45Z
dc.date.issued2016
dc.description.abstractIn this study, a pilot-scale, two-stage cascade biological nutrient removal (TSC-BNR) process with a 10 m(3). d(-1) capacity was used in order to remove carbon and nutrient from municipal wastewater. The process was composed of screens, a primary sedimentation tank, a distribution tank, an anaerobic tank, anoxic1/aerobic1/anoxic2/aerobic2 tanks, and a final sedimentation tank. Real (Sewer system) wastewater was fed to the pilot plant and the inflow was fed to the anaerobic and anoxic2 tanks at the same rates to eliminate the need for external carbon source in the second stage anoxic tank. The mixed liquor suspended solids (MLSS) concentration was kept between 4500 and 5500 mg.L-1 during the study. The sludge retention time was 15 days and the hydraulic retention time was 16 hours. The average concentrations of chemical oxygen demand (COD), total nitrogen (TN), ammonium nitrogen (NH4+-N), total phosphorus (TP), phosphate phosphorus (PO43--P), suspended solids (SS), and volatile suspended solids (VSS) in the influent were 555 mg.L-1, 71.9 mg.L-1, 44.0 mg.L-1, 8.1 mg.L-1, 4.0 mg.L-1, 316 mg.L-1, and 230 mg.L-1, respectively, the average removal efficiencies were 86.7 +/- 10.4%, 80.3 +/- 11.0%, 92.5 +/- 10.1%, 89.5 +/- 6.8%, 87.5 +/- 8.8%, 94.8 +/- 3.2%, and 95.0 +/- 3.4%, respectively. The results indicated that TSC-BNR process can be confidently used for the removal of carbon and nutrients from medium-strength municipal wastewaters.en
dc.description.sponsorshipYildiz Technical University Scientific Research Projects Coordination Department [2011-05-02-KAP05]
dc.identifier.eissn1304-7191
dc.identifier.endpage79
dc.identifier.issn1304-7205
dc.identifier.issue1
dc.identifier.startpage71
dc.identifier.urihttps://hdl.handle.net/20.500.14981/55614
dc.identifier.volume34
dc.identifier.wos000379847200006
dc.language.isoeng
dc.publisherYILDIZ TECHNICAL UNIV
dc.relation.ispartofSIGMA JOURNAL OF ENGINEERING AND NATURAL SCIENCES-SIGMA MUHENDISLIK VE FEN BILIMLERI DERGISI
dc.subjectBiological nutrient removal
dc.subjectcascade reactor
dc.subjectdomestic wastewater
dc.subjectSTEP FEED SYSTEM
dc.subjectNITROGEN REMOVAL
dc.subjectMICROBIAL COMMUNITY
dc.subjectMEMBRANE BIOREACTOR
dc.subjectPHOSPHORUS REMOVAL
dc.subjectCARBON SOURCE
dc.subjectPERFORMANCE
dc.subjectOPERATION
dc.subjectRATIO
dc.subjectEngineering
dc.titleMUNICIPAL WASTEWATER TREATMENT WITH A PILOT SCALE TWO-STAGE CASCADE BIOLOGICAL NUTRIENT REMOVAL PROCESS
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar