| dc.description.abstract | In this study, the electrocoagulation process was evaluated as a pretreatment process for olive mill wastewaters. Aluminium (Al) and iron (Fe) electrodes, several contact times and 0.5, 1 and 2 A currents were used to compare chemical oxygen demand (COD) removal efficiencies for each case. The optimum contact time and current were 45 minutes and 1 A, respectively, which resulted in a COD removal of 58.7% with an Al electrode. Experimental data from distinct operational conditions were used to fit a model for COD removal efficiencies. Energy consumption was also predicted. Under optimum operational conditions, the treatment cost was approximately (sic)0.13 kg(-1) CODremoved and (sic)4.41 m(-3). The results showed that the electrocoagulation process was a cost-effective method for the pretreatment of olive mill wastewaters. | en |
| dc.description.uri | https://doi.org/10.1080/09593330.2011.595829 | |
| dc.identifier.doi | 10.1080/09593330.2011.595829 | |
| dc.identifier.eissn | 1479-487X | |
| dc.identifier.endpage | 807 | |
| dc.identifier.issn | 0959-3330 | |
| dc.identifier.issue | 7 | |
| dc.identifier.pubmed | 22720403 | |
| dc.identifier.startpage | 801 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14981/51425 | |
| dc.identifier.volume | 33 | |
| dc.identifier.wos | 000303581300008 | |
| dc.language.iso | eng | |
| dc.publisher | TAYLOR & FRANCIS LTD | |
| dc.relation.ispartof | ENVIRONMENTAL TECHNOLOGY | |
| dc.subject | chemical oxygen demand removal | |
| dc.subject | electrocoagulation | |
| dc.subject | modelling | |
| dc.subject | olive mill wastewaters | |
| dc.subject | pretreatment | |
| dc.subject | WASTE-WATER TREATMENT | |
| dc.subject | ELECTROCHEMICAL TREATMENT | |
| dc.subject | PHENOLIC-COMPOUNDS | |
| dc.subject | REMOVAL | |
| dc.subject | OXIDATION | |
| dc.subject | FENTON | |
| dc.subject | DETOXIFICATION | |
| dc.subject | EFFLUENT | |
| dc.subject | INDUSTRY | |
| dc.subject | COD | |
| dc.subject | Environmental Sciences & Ecology | |
| dc.title | Optimization of energy costs in the pretreatment of olive mill wastewaters by electrocoagulation | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| local.import.source | WOS |