Yayın:
Systemic observation and measurement of microgap formation in dental implant-abutment connection interface under fatigue

dc.contributor.authorMercan, Cigdem
dc.contributor.authorBulutsuz, Asli Gunay
dc.contributor.authorKatiboglu, Ahmet Bulent
dc.date.accessioned2026-06-27T14:55:04Z
dc.date.issued2023
dc.description.abstractToday, a variety of implant designs with different attachment types are widely used in dental implant systems to eliminate connection problems. However, there are still design issues that can significantly affect the long-term success of dental implants. One of these problems is the formation of a microgap in the abutment-implant interface, which can lead to abutment screw loosening, screw fracture, and abutment fracture under masticatory loading. In this in vitro study, the effects of gingival height, dental implant diameter, and abutment type (solid, digital, and ball) on microgap formation were observed after repetitive fatigue tests using an experimental design. After the tests, the optimal design factors were determined to minimize microgap formation. According to the results of the experimental design, the abutment type was found to be the most influential parameter on microgap formation. An implant diameter of 4.1 mm, the smallest gingival height of 0.5 mm, and a digital attachment combination were identified as the optimal design parameters based on the statistical approach (R-2 = 85.3 %).en
dc.description.sponsorshipThe authors would like to thank Dental Implant KA for their implant support.
dc.description.urihttps://doi.org/10.1515/mt-2023-0071
dc.identifier.doi10.1515/mt-2023-0071
dc.identifier.eissn2195-8572
dc.identifier.endpage1685
dc.identifier.issn0025-5300
dc.identifier.issue11
dc.identifier.startpage1679
dc.identifier.urihttps://hdl.handle.net/20.500.14981/66190
dc.identifier.volume65
dc.identifier.wos001066330500001
dc.language.isoeng
dc.publisherWALTER DE GRUYTER GMBH
dc.relation.ispartofMATERIALS TESTING
dc.subjectmicrogap
dc.subjectfatigue test
dc.subjectexperimental design
dc.subjectdental implant-abutment interface
dc.subjectmeasurement
dc.subjectIN-VITRO EVALUATION
dc.subjectBACTERIAL-COLONIZATION
dc.subjectSTRESS-DISTRIBUTION
dc.subjectMICROBIAL LEAKAGE
dc.subject2-STAGE IMPLANTS
dc.subjectMARGINAL FIT
dc.subjectDIAMETER
dc.subjectLOAD
dc.subjectINFLAMMATION
dc.subjectMICROMOTION
dc.subjectMaterials Science
dc.titleSystemic observation and measurement of microgap formation in dental implant-abutment connection interface under fatigue
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar