Yayın:
Selective Amperometric Sensor for the Determination of Hydrazine at a Gold Nanoparticle Decorated Poly(Brilliant Blue) Modified Electrode

dc.contributor.authorDokur, Ebrar
dc.contributor.authorUruc, Selen
dc.contributor.authorSuerkan, Sevdanur
dc.contributor.authorGorduk, Ozge
dc.contributor.authorSahin, Yucel
dc.date.accessioned2026-06-27T15:05:58Z
dc.date.issued2025
dc.description.abstractThere is a pressing requirement to synthesize stable electrode components that possess enhanced capabilities for creating electrochemical sensors, which are sensitive and discerning, to swiftly detect dangerous noxious substances. A sensitive electrochemical sensor has been developed in this study for hydrazine (HY) oxidation, utilizing gold nanoparticles (AuNPs) and poly(brilliant blue) (p(BB)) modifiers on the surface of the pencil graphite electrode (PGE). The features of the sensor for detecting hydrazine were characterized by electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and X-ray photoelectron spectroscopy (XPS). Additionally, when examined under optimal parameters using CV and amperometry, the proposed hydrazine sensor presents favorable electrochemical and analytical figures of merit. The AuNPs/p(BB)/PGE provides the determination of low levels of hydrazine in water samples with a detection limit of 0.14 mu M. A wide linear range from 1.0 to 800 mu M was obtained. The findings indicate that the AuNPs/p(BB)/PGE sensor exhibits good stability, repeatability, and reproducibility for hydrazine. The proposed sensor was effectively used to determine hydrazine in both water and mineral water samples.en
dc.description.urihttps://doi.org/10.1080/00032719.2024.2317873
dc.identifier.doi10.1080/00032719.2024.2317873
dc.identifier.eissn1532-236X
dc.identifier.endpage1951
dc.identifier.issn0003-2719
dc.identifier.issue12
dc.identifier.startpage1931
dc.identifier.urihttps://hdl.handle.net/20.500.14981/67903
dc.identifier.volume58
dc.identifier.wos001179546100001
dc.language.isoeng
dc.publisherTAYLOR & FRANCIS INC
dc.relation.ispartofANALYTICAL LETTERS
dc.subjectElectrochemical analysis
dc.subjectgold nanoparticles (AuNPs)
dc.subjecthydrazine
dc.subjectpencil graphite electrode (PGE)
dc.subjectpoly(brilliant blue)
dc.subjectPENCIL GRAPHITE ELECTRODE
dc.subjectELECTROCATALYTIC OXIDATION
dc.subjectELECTROCHEMICAL SENSOR
dc.subjectCARBON NANOTUBES
dc.subjectCATECHOL
dc.subjectPALLADIUM
dc.subjectPASTE
dc.subjectChemistry
dc.titleSelective Amperometric Sensor for the Determination of Hydrazine at a Gold Nanoparticle Decorated Poly(Brilliant Blue) Modified Electrode
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar