Yayın:
Shear Capacity of Masonry Walls Externally Strengthened via Reinforced Khorasan Jacketing

dc.contributor.authorMollamahmutoglu, Cagri
dc.contributor.authorOzturk, Mehdi
dc.contributor.authorYilmaz, Mehmet Ozan
dc.date.accessioned2026-06-27T15:20:06Z
dc.date.issued2025
dc.description.abstractThis study investigates the in-plane shear behavior of solid brick masonry walls, both unreinforced and retrofitted using Reinforced Khorasan Jacketing (RHJ), a traditional pozzolanic mortar technique rooted in Iranian and Ottoman architecture. Six one-block-thick English bond masonry walls were tested in three configurations: unreinforced with Horasan plaster (Group I), reinforced with steel mesh aligned to wall edges (Group II), and reinforced with mesh aligned diagonally (Group III). All the walls were plastered with 3.5 cm of Horasan mortar and tested after 18 months using diagonal compression, with load-displacement data recorded. A detailed 3D micro-modeling approach was employed in finite element simulations, with bricks and mortar modeled separately. The Horasan mortar was represented using an elastoplastic Mohr-Coulomb model with a custom softening law (parabolic-to-exponential), calibrated via inverse parameter fitting using the Nelder-Mead algorithm. The numerical predictions closely matched the experimental data. Reinforcement improved the shear strength significantly: Group II showed a 1.8 times increase, and Group III up to 2.7 times. Ductility, measured as post-peak deformation capacity, increased by factors of two (parallel) and three (diagonal). These enhancements transformed the brittle failure mode into a more ductile, energy-absorbing behavior. RHJ is shown to be a compatible, effective retrofit solution for historic masonry structures.en
dc.description.urihttps://doi.org/10.3390/buildings15132177
dc.identifier.doi10.3390/buildings15132177
dc.identifier.eissn2075-5309
dc.identifier.issue13
dc.identifier.urihttps://hdl.handle.net/20.500.14981/69853
dc.identifier.volume15
dc.identifier.wos001533826600001
dc.language.isoeng
dc.publisherMDPI
dc.relation.ispartofBUILDINGS
dc.rightsopenAccess
dc.subjectKhorasan (Horasan) mortar
dc.subjectmasonry
dc.subjectdiagonal compression test
dc.subjectmechanical properties
dc.subjectshear capacity
dc.subjectwall jacketing
dc.subjectmicro-modeling
dc.subjectinverse parameter fitting
dc.subjectBEHAVIOR
dc.subjectFRP
dc.subjectPANELS
dc.subjectFERROCEMENT
dc.subjectCONCRETE
dc.subjectMORTAR
dc.subjectConstruction & Building Technology
dc.subjectEngineering
dc.titleShear Capacity of Masonry Walls Externally Strengthened via Reinforced Khorasan Jacketing
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar