Yayın: Determination of hydrocortisone and cortisone in artificial saliva by spray assisted fine droplet formation liquid phase microextraction coupled to LC-MS/MS
| dc.contributor.author | Gursoy, Selim | |
| dc.contributor.author | Bodur, Suleyman | |
| dc.contributor.author | Atakol, Arda | |
| dc.contributor.author | Bakirdere, Sezgin | |
| dc.date.accessioned | 2026-06-27T15:32:46Z | |
| dc.date.issued | 2026 | |
| dc.description.abstract | Hydrocortisone and cortisone are clinically informative steroids whose joint measurement at low concentrations is essential for ratio-reliable interpretation. A spraying-assisted fine droplet formation liquid-phase microextraction (SA-FDF-LPME) was combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) for simultaneous quantitation in saliva-type matrices as part of a method-development study. Method parameters were optimized to secure chromatographic resolution, stable ion ratios, and high sensitivity. Under direct injection, LOD/LOQ values were 1.05/3.50 & micro;g kg-1 for cortisone and 0.80/2.68 & micro;g kg-1 for hydrocortisone, with dynamic ranges of 3.65-150.77 and 2.59-268.45 & micro;g kg-1, respectively. With SA-FDF-LPME coupled to LC-MS/MS, LOD/LOQ were 0.0164/0.0547 & micro;g kg-1 for cortisone and 0.0734/0.245 & micro;g kg-1 for hydrocortisone, and dynamic ranges were 0.049-4.983 and 0.210-5.50 & micro;g kg-1, respectively. Accuracy was established by pre-extraction spiking at different concentrations in two artificial saliva formulations. Using external-standard calibration, recoveries were 105.3-129.4%/110.4-141.1% for cortisone and 110.0-134.9%/94.1-142.8% for hydrocortisone; with matrix-matched calibration, recoveries were 80.3-103.2%/98.1-117.8% for cortisone and 79.8-105.7%/97.3-114.0% for hydrocortisone. The developed SA-FDF-LPME-LC-MS/MS method enables sensitive, accurate, and simultaneous quantification of hydrocortisone and cortisone at saliva-relevant concentrations and offers a practical platform for selective bioanalysis of related small molecules. | en |
| dc.description.uri | https://doi.org/10.1038/s41598-026-38457-z | |
| dc.identifier.doi | 10.1038/s41598-026-38457-z | |
| dc.identifier.issn | 2045-2322 | |
| dc.identifier.issue | 1 | |
| dc.identifier.pubmed | 41634132 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14981/71777 | |
| dc.identifier.volume | 16 | |
| dc.identifier.wos | 001696310800028 | |
| dc.language.iso | eng | |
| dc.publisher | NATURE PORTFOLIO | |
| dc.relation.ispartof | SCIENTIFIC REPORTS | |
| dc.rights | openAccess | |
| dc.subject | Artificial saliva | |
| dc.subject | Hydrocortisone | |
| dc.subject | Cortisone | |
| dc.subject | Spraying assisted fine droplet formation liquid phase microextraction | |
| dc.subject | Tandem mass spectrometry | |
| dc.subject | TANDEM MASS-SPECTROMETRY | |
| dc.subject | 11-BETA-HYDROXYSTEROID DEHYDROGENASE | |
| dc.subject | URINE | |
| dc.subject | VALIDATION | |
| dc.subject | PLASMA | |
| dc.subject | SERUM | |
| dc.subject | Science & Technology - Other Topics | |
| dc.title | Determination of hydrocortisone and cortisone in artificial saliva by spray assisted fine droplet formation liquid phase microextraction coupled to LC-MS/MS | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| local.import.source | WOS |