dc.description.abstractIn this study, the electrocoagulation (EC) technique for tannery wastewater treatment was examined using iron and aluminum electrodes. The effects of operating parameters that include current density, initial pH, and electrolysis time on EC performance were accomplished. In addition, Taguchi method was carried out in order to design the experiments and to optimize the experimental results. L-25 orthogonal array (OA, three factors in five levels), signal-to-noise (S/N) ratio (the larger-the-better), and analysis of variance were applied to find the optimum levels and relative magnitude of the effects of parameters. The removal efficiency of chemical oxygen demand (COD), total chrome, and color are considered as the response parameters. In the case of iron electrodes, the optimum conditions of COD were found to be at the fifth level of current density (50mA/cm(2)), the fourth level of initial pH (7), and fifth level of electrolysis time (25min). According to total chrome, they were found at the third level of current density (30mA/cm(2)), the fifth level of initial pH (8), and the fifth level of electrolysis time (25min). In addition, with regard to color removal efficiency, they were determined to be at the fifth level of current density (50mA/cm(2)), the fourth level of initial pH (7), and the fifth level of electrolysis time (25min). At the optimum conditions of COD, total chrome and color removal efficiencies were achieved as 63.3, 99.7, and 82%, respectively. Also, operating costs for both COD and color removals were evaluated as 0.88$/m(3); but for chrome removal, they were 0.70$/m(3). In the case of aluminum electrode, the optimum conditions of COD, total chrome, and color removal were found to be at the fifth level for each operating parameter corresponding to current density (50mA/cm(2)), initial pH (7), and electrolysis time (25min). As a result, the observed removal efficiencies of COD, total chrome, and color under these optimum conditions were 64.4, 99, and 88%, respectively. In addition, operating costs for COD, chrome, and color removals were 0.94$/m(3).en
dc.description.sponsorshipYTU-Office of Scientific Research Project Coordination [2012-05-02KAP02]
dc.description.urihttps://doi.org/10.1080/19443994.2015.1074622
dc.identifier.doi10.1080/19443994.2015.1074622
dc.identifier.eissn1944-3986
dc.identifier.endpage14809
dc.identifier.issn1944-3994
dc.identifier.issue32
dc.identifier.startpage14798
dc.identifier.urihttps://hdl.handle.net/20.500.14981/54917
dc.identifier.volume57
dc.identifier.wos000373516300002
dc.language.isoeng
dc.publisherDESALINATION PUBL
dc.relation.ispartofDESALINATION AND WATER TREATMENT
dc.subjectTaguchi method
dc.subjectElectrocoagulation
dc.subjectAluminum electrodes
dc.subjectIron electrodes
dc.subjectTotal chrome
dc.subjectTannery wastewater
dc.subjectEXPERIMENTAL-DESIGN
dc.subjectREMOVAL
dc.subjectCOAGULATION
dc.subjectPOLLUTANTS
dc.subjectEFFLUENTS
dc.subjectINDUSTRY
dc.subjectREACTOR
dc.subjectEngineering
dc.subjectWater Resources
dc.titleTreatment of raw tannery wastewater by electrocoagulation technique: optimization of effective parameters using Taguchi method
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar