Yayın:
Speciation of Arsenic in Fish by High-Performance Liquid Chromatography-Inductively Coupled Plasma-Mass Spectrometry

dc.contributor.authorOzcan, Sefika
dc.contributor.authorBakirdere, Sezgin
dc.contributor.authorAtaman, Osman Yavuz
dc.date.accessioned2026-06-27T13:55:31Z
dc.date.issued2016
dc.description.abstractArsenic speciation in fish was performed using isocratic elution with cation exchange column high-performance liquid chromatography and inductively coupled plasma-mass spectrometry detection. The separation of arsenobetaine and dimethylarsinic acid was performed in 12 min. DOLT-4 dogfish liver and NIST RM-50 albacore tuna certified reference materials were used to evaluate the accuracy for the determination of total arsenic in fish. In addition, reference materials were analyzed for arsenobetaine and dimethylarsinic acid, although they were not certified for these analytes. The limits of detection for arsenic in arsenobetaine and dimethylarsinic acid were 0.20 and 0.33 ng/mL, and the limits of quantitation were 0.58 and 1.11 ng/mL, respectively. Total arsenic and arsenic species were determined in fish using the developed method. The predominant arsenic species was arsenobetaine; the measured concentrations were from 0.43 to 12.0 mg/kg arsenic as arsenobetaine. Dimethylarsinic acid concentrations were below the limit of quantitation. The relative standard deviations were between 3.36 and 10.49 for total arsenic and 3.51 and 9.30 for arsenobetaine.en
dc.description.sponsorshipMiddle East Technical University [BAP-07-02-2009-00-03, BAP-01-03-2009-01]
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TUBITAK) [TBAG-103T157]
dc.description.urihttps://doi.org/10.1080/00032719.2016.1151887
dc.identifier.doi10.1080/00032719.2016.1151887
dc.identifier.eissn1532-236X
dc.identifier.endpage2512
dc.identifier.issn0003-2719
dc.identifier.issue15
dc.identifier.startpage2501
dc.identifier.urihttps://hdl.handle.net/20.500.14981/55779
dc.identifier.volume49
dc.identifier.wos000383714500012
dc.language.isoeng
dc.publisherTAYLOR & FRANCIS INC
dc.relation.ispartofANALYTICAL LETTERS
dc.subjectArsenic
dc.subjectarsenobetaine
dc.subjectfish
dc.subjectspeciation
dc.subjectATOMIC-ABSORPTION SPECTROMETRY
dc.subjectHPLC-ICP-MS
dc.subjectFLUORESCENCE DETECTION
dc.subjectBIOLOGICAL SAMPLES
dc.subjectEXTRACTION
dc.subjectSEAFOOD
dc.subjectENVIRONMENT
dc.subjectTRIVALENT
dc.subjectChemistry
dc.titleSpeciation of Arsenic in Fish by High-Performance Liquid Chromatography-Inductively Coupled Plasma-Mass Spectrometry
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar