Yayın:
Combination of ultrasound-assisted ethyl chloroformate derivatization and switchable solvent liquid-phase microextraction for the sensitive determination of l-methionine in human plasma by GC-MS

dc.contributor.authorErarpat, Sezin
dc.contributor.authorBodur, Suleyman
dc.contributor.authorOzturk Er, Elif
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T14:27:42Z
dc.date.issued2020
dc.description.abstractA green and fast analytical method for the determination of l-methionine in human plasma is presented in this study. Preconcentration of the analyte was carried out by switchable solvent liquid phase microextraction after ethyl chloroformate derivatization reaction. Instrumental detection of the analyte was performed by means of gas chromatography-mass spectrometry. N,N-Dimethyl benzylamine was used in the synthesis of switchable solvent. Protonated N,N-dimethyl benzylamine volume, volume/concentration of sodium hydroxide, and vortex period were meticulously fixed to their optimum values. Besides, ethyl chloroformate, pyridine, and ethanol volumes were optimized in order to get high derivatization yield. After the optimization studies, limit of detection and quantitation values were attained as 3.30 and 11.0 ng/g, respectively, by the developed switchable solvent liquid phase microextraction gas chromatography-mass spectrometry method that corresponding to 76.7-folds enhancement in detection power of the gas chromatography-mass spectrometry system. Applicability and accuracy of the switchable solvent liquid phase microextraction-gas chromatography-mass spectrometry method were also checked by spiking experiments. Percent recovery results were ranged from 97.8 to 100.5% showing that human plasma samples could be analyzed for its l-methionine level by the proposed method.en
dc.description.urihttps://doi.org/10.1002/jssc.201901078
dc.identifier.doi10.1002/jssc.201901078
dc.identifier.eissn1615-9314
dc.identifier.endpage1106
dc.identifier.issn1615-9306
dc.identifier.issue6
dc.identifier.pubmed31858708
dc.identifier.startpage1100
dc.identifier.urihttps://hdl.handle.net/20.500.14981/60871
dc.identifier.volume43
dc.identifier.wos000506091400001
dc.language.isoeng
dc.publisherWILEY-V C H VERLAG GMBH
dc.relation.ispartofJOURNAL OF SEPARATION SCIENCE
dc.subjectgas chromatography
dc.subjecthuman plasma
dc.subjectmethionine
dc.subjectswitchable solvent
dc.subjectCHROMATOGRAPHY-MASS SPECTROMETRY
dc.subjectAMINO-ACID-ANALYSIS
dc.subjectGAS-CHROMATOGRAPHY
dc.subjectHYDROPHILICITY SOLVENT
dc.subjectFOOD SAMPLES
dc.subjectL-CYSTEINE
dc.subjectELECTRODE
dc.subjectWATER
dc.subjectIONIZATION
dc.subjectEXTRACTION
dc.subjectChemistry
dc.titleCombination of ultrasound-assisted ethyl chloroformate derivatization and switchable solvent liquid-phase microextraction for the sensitive determination of l-methionine in human plasma by GC-MS
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar