Yayın: ASSESSMENT OF WIND PRESSURE BY EUROCODE-1, TS 498 AND CFD ANALYSES FOR DOUBLE-SLOPED ROOF BUILDING
| dc.contributor.author | Zeyrek, Halil | |
| dc.contributor.author | Bekiroglu, Serkan | |
| dc.date.accessioned | 2026-06-27T14:19:55Z | |
| dc.date.issued | 2019 | |
| dc.description.abstract | In this study, building external wall pressures induced by wind velocity for rectangular planned-buildings with several roof slopes are determined using two wind standards such as Eurocode-1 and TS 498 and two-dimensional computational fluid dynamics (CFD) analysis. In CFD analyses, wind velocity function produced according to Eurocode-1 is used as velocity input. At the end of the study, wall pressures obtained by using Eurocode-1, TS 498 and CFD analyses are compared on the same peripheral region of the buildings. It is concluded that the results of TS 498 are not at a sufficient level according to the results of Eurocode-1 and CFD analyses. The results of Eurocode-1 and CFD analyses match with each other regarding positive and negative pressures on the same peripheral region. Eurocode-1 propounds higher values than those of CFD except values obtained on regions at the folded-corners of some buildings. | en |
| dc.identifier.eissn | 1304-7191 | |
| dc.identifier.endpage | 272 | |
| dc.identifier.issn | 1304-7205 | |
| dc.identifier.issue | 1 | |
| dc.identifier.startpage | 251 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14981/59353 | |
| dc.identifier.volume | 37 | |
| dc.identifier.wos | 000462503900021 | |
| dc.language.iso | eng | |
| dc.publisher | YILDIZ TECHNICAL UNIV | |
| dc.relation.ispartof | SIGMA JOURNAL OF ENGINEERING AND NATURAL SCIENCES-SIGMA MUHENDISLIK VE FEN BILIMLERI DERGISI | |
| dc.subject | Computational fluid dynamics (CFD) analyses | |
| dc.subject | Eurocode-1 (TS EN 1991-1-4) | |
| dc.subject | TS 498 | |
| dc.subject | rectangular planned to build with double-sloped roof | |
| dc.subject | external wall pressure | |
| dc.subject | wind velocity function | |
| dc.subject | Engineering | |
| dc.title | ASSESSMENT OF WIND PRESSURE BY EUROCODE-1, TS 498 AND CFD ANALYSES FOR DOUBLE-SLOPED ROOF BUILDING | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| local.import.source | WOS |