Yayın:
Determination of phenytoin at trace levels in domestic wastewater and synthetic urine samples by gas chromatography-mass spectrometry after its preconcentration by simple liquid-phase microextraction

dc.contributor.authorBodur, Sezin Erarpat
dc.contributor.authorAyan, Gizem Nur
dc.contributor.authorBodur, Suleyman
dc.contributor.authorGunkara, Omer Tahir
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T15:06:49Z
dc.date.issued2024
dc.description.abstractThis work presents a sensitive and accurate analytical method for the determination of phenytoin at trace levels in domestic wastewater and synthetic urine samples by gas chromatography-mass spectrometry (GC-MS) after the metal sieve-linked double syringe liquid-phase microextraction (MSLDS-LPME) method. A metal sieve was produced in our laboratory in order to disperse water-immiscible extraction solvents into aqueous media. Univariate optimization studies for the selection of proper extraction solvent, extraction solvent volume, mixing cycle, and initial sample volume were carried out. Under the optimum MSLDS-LPME conditions, mass-based dynamic range, limit of quantitation (LOQ), limit of detection (LOD), and percent relative standard deviation (%RSD) for the lowest concentration in calibration plot were figured out to be 100.5-10964.2 mu g kg-1, 150.6 mu g kg-1, 45.2 mu g kg-1, and 9.4%, respectively. Detection power was improved as 187.7-folds by the developed MSLDS-LPME-GC-MS system while enhancement in calibration sensitivity was recorded as 188.0-folds. In the final step of this study, the accuracy and applicability of the proposed system were tested by matrix matching calibration strategy. Percent recovery results for domestic wastewater and synthetic urine samples were calculated as 95.6-110.3% and 91.7-106.6%, respectively. These results proved the accuracy and applicability of the proposed preconcentration method, and the obtained analytical results showed the efficiency of the lab-made metal sieve apparatus.en
dc.description.sponsorshipYildiz Technical University Scientific Research Project [FYL-2022-4855]
dc.description.urihttps://doi.org/10.1007/s10661-024-12544-y
dc.identifier.doi10.1007/s10661-024-12544-y
dc.identifier.eissn1573-2959
dc.identifier.issn0167-6369
dc.identifier.issue5
dc.identifier.pubmed38622372
dc.identifier.urihttps://hdl.handle.net/20.500.14981/68085
dc.identifier.volume196
dc.identifier.wos001204732500001
dc.language.isoeng
dc.publisherSPRINGER
dc.relation.ispartofENVIRONMENTAL MONITORING AND ASSESSMENT
dc.subjectPhenytoin
dc.subjectMetal sieve-linked double syringe liquid-phase microextraction
dc.subjectGas chromatography-mass spectrometry
dc.subjectDomestic wastewater
dc.subjectUrine
dc.subjectHUMAN PLASMA
dc.subjectANTIEPILEPTIC DRUGS
dc.subjectEXTRACTION
dc.subjectSORBENT
dc.subjectEnvironmental Sciences & Ecology
dc.titleDetermination of phenytoin at trace levels in domestic wastewater and synthetic urine samples by gas chromatography-mass spectrometry after its preconcentration by simple liquid-phase microextraction
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar