Yayın:
Determination of optimum insulation thickness for building walls by using heating and cooling degree-day values of all Turkey's provincial centers

dc.contributor.authorKurekci, Nuri Alpay
dc.contributor.institutionauthorKÜREKCİ, Nuri Alpay
dc.date.accessioned2026-06-27T13:46:41Z
dc.date.issued2016
dc.description.abstractThe energy requirement of developing countries such as Turkey increase every single year. The energy consumption of this country is divided into four main sectors: industrial, residential, transportation and agriculture. The residential sector accounts for 33% of used energy. Uninsulated old buildings, as well as inadequate insulation in new construction poses massive economic burden to this country, forcing it to over-rely on fuels from abroad. In this study, the optimum insulation thicknesses required in Turkey's 81 provincial centers are determined. The calculations are made on the basis of four different fuels (natural gas, coal, fuel oil and liquefied petroleum gas) and 5 different insulation materials (extruded polystyrene, expanded polystyrene, glass wool, rock wool and polyurethane). Three different cases have been considered: buildings heated but not cooled, cooled but not heated, and both heated and cooled; optimum required insulation thicknesses in accordance with each case are calculated. Optimum insulation thicknesses, total net saving amount, reimbursement period change according to the fuels and insulation materials are calculated on the basis of 5 different provincial centers (Izmir, Istanbul, Ankara, Sivas and Erzurum) selected according to their degree/day values. (C) 2016 Elsevier B.V. All rights reserved.en
dc.description.urihttps://doi.org/10.1016/j.enbuild.2016.03.004
dc.identifier.doi10.1016/j.enbuild.2016.03.004
dc.identifier.eissn1872-6178
dc.identifier.endpage213
dc.identifier.issn0378-7788
dc.identifier.startpage197
dc.identifier.urihttps://hdl.handle.net/20.500.14981/54703
dc.identifier.volume118
dc.identifier.wos000374369500020
dc.language.isoeng
dc.publisherELSEVIER SCIENCE SA
dc.relation.ispartofENERGY AND BUILDINGS
dc.subjectOptimum insulation thickness
dc.subjectEnergy saving
dc.subjectHeating and cooling degree-day value
dc.subjectEXTERNAL WALLS
dc.subjectENERGY
dc.subjectCLIMATE
dc.subjectRESPECT
dc.subjectREGIONS
dc.subjectConstruction & Building Technology
dc.subjectEnergy & Fuels
dc.subjectEngineering
dc.titleDetermination of optimum insulation thickness for building walls by using heating and cooling degree-day values of all Turkey's provincial centers
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar