Energy and economic analysis of the bypass method for the computer room air conditioning units of a small data center

dc.contributor.authorErden, Hamza Salih
dc.contributor.authorTurkmen, Ismail
dc.date.accessioned2026-06-27T14:44:25Z
dc.date.issued2022
dc.description.abstractEarlier optimization studies utilized reduced-order modeling approach combining flow network modeling at room level and thermodynamic modeling at the cooling infrastructure level to investigate the energy saving potential of the computer room air handling (CRAH) bypass (BP) method for data centers. Flow network modeling worked well in predicting the cooling infrastructure power use at various BP fractions. While existing studies are either on hypothetical data centers or experimental setups, there is no considerable work on the feasibility of the method in real and operational data center. Economic requirements of the method is another aspect missing in the literature. This study includes assessments on the feasibility of the CRAH BP methods (forced and induced) in an operational data center using reduced-order modeling approaches suggested in the literature. As a result of the energy and economic analysis of various scenarios, it has been concluded that the feasibility of the CRAH BP method is directly related to the number of fans required by the design and recommendations for application have been proposed.en
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TUBITAK) [118M238]
dc.description.urihttps://doi.org/10.17341/gazimmfd.897270
dc.identifier.doi10.17341/gazimmfd.897270
dc.identifier.eissn1304-4915
dc.identifier.endpage1898
dc.identifier.issn1300-1884
dc.identifier.issue4
dc.identifier.startpage1883
dc.identifier.urihttps://hdl.handle.net/20.500.14981/64165
dc.identifier.volume37
dc.identifier.wos000767316300013
dc.language.isoeng
dc.publisherGAZI UNIV, FAC ENGINEERING ARCHITECTURE
dc.relation.ispartofJOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY
dc.rightsopenAccess
dc.subjectEnergy efficiency
dc.subjectdata centers
dc.subjectcooling infrastructure
dc.subjecteconomics
dc.subjectmodeling & optimization
dc.subjectINDUCED CRAH BYPASS
dc.subjectOPTIMIZATION
dc.subjectPERFORMANCE
dc.subjectCOST
dc.subjectEngineering
dc.titleEnergy and economic analysis of the bypass method for the computer room air conditioning units of a small data center
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar