Yayın:
Optimal design of a solar-driven Kalina system for combined power and desalination purposes

Yükleniyor...
Küçük Resim

Tarih

Kurum Yazarları

Danışman

item.page.editor

Editör

Bölüm / Program

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

PERGAMON-ELSEVIER SCIENCE LTD

DOI

10.1016/j.solener.2023.112277

Türü

View PlumX Details

Araştırma Projeleri

Akademik Birimler

Dergi Sayısı

Özet

This research study presents a thermodynamic simulation and exergy analysis of a solar-powered Kalina cycle that is integrated with a reverse osmosis desalination (RO) module and a thermoelectric generator (TEG) system. A parabolic through solar collector (PTSC) provides the required heat to drive designed plant. The thermodynamic simulation and exergy examination of the proposed system are carried out using the Engineering Equation Solver (EES). A parametric study of the presented plant to show the primary parameters impacts on the system operation is conducted. The system in this study generates 212.7 kW of electrical power and 44.46 m3/h. The total energy efficiency of the plant is 24.3 %. The inlet thermal energy from PTSC is 876.5 kW. In addition, the thermoelectric module generates 7.26 kW electrical power. Carried out analyses show that the recuperator has the most significant exergy destruction rate among all system components, with 303.2 kW. The unit responsible for the second major exergy destruction value associated with the RO unit, which accounts for 74.22 kW. To examine the influence of influences of parameters like direct normal irradiance (DNI), turbine inlet pressure, and mass flow rate of the Kalina cycle the system case study is presented. It can be observed that increasing DNI parameter from 750 W/m2 to 1000 W/m2 leads in a net output power increment from 279.1 kW to 372.1 kW and increasing fresh-water production from 41.64 m3/h to 48.09 m3/h. Moreover, the calculation shows that increasing DNI has a positive impact on the TEG unit output power too. Enhancing the inlet turbine pressure increases both net output power and fresh-water production by reverse osmosis unit while this increment diminishes the thermoelectric unit electrical output. It can be observed that increasing turbine inlet pressure from 110 kPa to 200 kPa, increases net output power and fresh-water production by about 6.08 % and 3.5 %, respectively.

Tanım

Dergi veya Seri

SOLAR ENERGY

ISSN

0038-092X

ISBN

Haklar

Alıntı

Koleksiyonlar

Onay

Gözden geçir

Tamamlayıcı Bilgiler

Referans Gösteren

Related Patent

Related Goal

0

Views

0

Downloads