Yayın:
Influence of 4,4,4-Trifluoro-1-phenyl-1,3-butanedione on Selectivity of All-Solid-State Lithium Ion Electrode Prepared by Using 6,6-Dibenzyl-1,4,8-11-tetraoxacyclotetradecane as Ionophore and Its Application in Human Serum Analysis

dc.contributor.authorYildirim, Ridvan
dc.contributor.authorAgir, Ismail
dc.contributor.authorNigde, Mustafa
dc.contributor.authorIsildak, Ibrahim
dc.date.accessioned2026-06-27T14:33:40Z
dc.date.issued2020
dc.description.abstractIn this work, we aimed to increase the selectivity of lithium selective electrodes containing lithium ionophore VI in the membrane matrix by using 4,4,4-Trifluoro-1-phenyl-1,3-butanedione (HBTA). Potentiometric response characteristics of the prepared lithium selective electrodes were investigated. Increasing the ratio of HBTA molecule in the membrane cocktail from 0.5% to 1.5% provided a better response with respect to the lower detection limit (LDL), linear range, and selectivity. The LDL and linear range of the electrode with 1.5% HBTA were 7.6x 10(-6) mol L-1 and 1.0x 10(-1) - 3.4x 10(-5) mol L-1 respectively, with a slope 54.3 mV/decade (R-2 = 0.9998). The potentiometric responses of all electrodes were pH-independent in the range of pH 3-12. The response time of the electrodes was less than 10 s and the lifetime was more than eight weeks. The electrode with 1.5% HBTA showed a better selectivity against sodium (1:575) and potassium (1:270) and was successfully applied for the determination of lithium levels in diluted human serum samples. The obtained potentiometric data were compared with the ICP-MS results at 98% confidence level.en
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TUBITAK) [2211]
dc.description.sponsorshipResearch Fund of the Yildiz Technical University [2015-07-04-KAP06]
dc.description.urihttps://doi.org/10.20964/2020.11.30
dc.identifier.doi10.20964/2020.11.30
dc.identifier.endpage11478
dc.identifier.issn1452-3981
dc.identifier.issue11
dc.identifier.startpage11468
dc.identifier.urihttps://hdl.handle.net/20.500.14981/62084
dc.identifier.volume15
dc.identifier.wos000591930300065
dc.language.isoeng
dc.publisherELSEVIER
dc.relation.ispartofINTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE
dc.rightsopenAccess
dc.subjectPVC membrane
dc.subjectall-solid-state contact electrode
dc.subjectbipolar disorder
dc.subjectlithium
dc.subjectpotentiometry
dc.subjectBIPOLAR
dc.subjectRECOMMENDATIONS
dc.subjectSPECTROMETRY
dc.subjectCHLORIDE
dc.subjectTHERAPY
dc.subjectElectrochemistry
dc.titleInfluence of 4,4,4-Trifluoro-1-phenyl-1,3-butanedione on Selectivity of All-Solid-State Lithium Ion Electrode Prepared by Using 6,6-Dibenzyl-1,4,8-11-tetraoxacyclotetradecane as Ionophore and Its Application in Human Serum Analysis
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar