Yayın: Development of Fe3O4/reduced graphene oxide nanocomposite-based dispersive solid-phase extraction for the quantification of five steroid hormones
| dc.contributor.author | Cagatay, Nese Ular | |
| dc.contributor.author | Mavis, Murat Emrah | |
| dc.contributor.author | Erarpat, Sezin | |
| dc.contributor.author | Bakirdere, Sezgin | |
| dc.date.accessioned | 2026-06-27T14:54:56Z | |
| dc.date.issued | 2023 | |
| dc.description.abstract | Aim: An accurate and sensitive analytical method was proposed to detect some steroid hormones in biological samples. Materials & methods: An Fe3O4/reduced graphene oxide nanocomposite-based dispersive solid-phase extraction was developed for the effective and simple preconcentration of steroid hormones from human serum samples. Results & conclusion: The nanocomposite was firstly used as adsorbent to simultaneously extract the selected hormones. Limit of detection values for the selected hormones were calculated between 5.5 and 39.2 ng/kg (mass based). An artificial serum sample was used to test the applicability and accuracy of the developed method; percentage recovery results obtained from two different spiked concentrations were found to be in the range of 80.5-99.9%. | en |
| dc.description.uri | https://doi.org/10.4155/bio-2023-0025 | |
| dc.identifier.doi | 10.4155/bio-2023-0025 | |
| dc.identifier.eissn | 1757-6199 | |
| dc.identifier.endpage | 512 | |
| dc.identifier.issn | 1757-6180 | |
| dc.identifier.issue | 9 | |
| dc.identifier.pubmed | 37125877 | |
| dc.identifier.startpage | 503 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14981/66162 | |
| dc.identifier.volume | 15 | |
| dc.identifier.wos | 000983118100001 | |
| dc.language.iso | eng | |
| dc.publisher | TAYLOR & FRANCIS LTD | |
| dc.relation.ispartof | BIOANALYSIS | |
| dc.subject | dispersive solid-phase extraction | |
| dc.subject | liquid chromatography-tandem mass spectrometry | |
| dc.subject | magnetic nanoparticles | |
| dc.subject | serum samples | |
| dc.subject | steroid hormones | |
| dc.subject | LC-MS/MS | |
| dc.subject | LIQUID-EXTRACTION | |
| dc.subject | HUMAN SERUM | |
| dc.subject | MICROEXTRACTION | |
| dc.subject | Biochemistry & Molecular Biology | |
| dc.subject | Chemistry | |
| dc.title | Development of Fe3O4/reduced graphene oxide nanocomposite-based dispersive solid-phase extraction for the quantification of five steroid hormones | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| local.import.source | WOS |