Yayın: Sensitive and accurate determination of oil-soluble and water-soluble organosulfur compounds in garlic matrix using reversed phase-high performance liquid chromatography
| dc.contributor.author | Polat Korkunc, Ummugulsum | |
| dc.contributor.author | Zaman, Buse Tugba | |
| dc.contributor.author | Bakirdere, Sezgin | |
| dc.contributor.author | Karakus, Emine | |
| dc.date.accessioned | 2026-06-27T15:05:51Z | |
| dc.date.issued | 2024 | |
| dc.description.abstract | Garlic is in the family Liliaceae and has many different constituents such as organic sulfur compounds, amino acids, carbohydrates, minerals, andvitamins. In this work, a simple, sensitive, and accurate analytical method was developed for the determination of selected organosulfur compounds (OSCs) in garlic bulbs using reversed phase -high performance liquid chromatography (RP-HPLC). Oil -soluble and water-soluble OSCs were extracted from the garlic samples via acetonitrile and deionized water, respectively. The OSCs were separated on a Phenomenex C18 (250 mm, 4 mm, 5mm) column and the monitoring was performed with a UV detector at nm. An isocratic mobile phase comprising of 0.10 M trifluoroacetic acid (TFA) in 85% acetonitrile (ACN) and 0.10 M TFA in distilled water (DW) (90: 10% v/v) was used to elute the analytes. Under optimum experimental conditions, the limits of detection (LOD) the analytes were calculated in the range of 0.09 to 0.17 mg/kg. For the garlic sample extracts analyzed under optimal instrumental conditions, DAS (diallyl sulfide), DADS (diallyl disulfide), and DATS (diallyl trisulfide) were detected in the ranges of 8.0 to 32.5 kg, 20.4 to 67.3 mg/kg, and 60.7 to 356.6 mg/kg, respectively. Spiked recovery experiments were conducted on the garlic samples confirm the method's applicability and accuracy. The recovery results ranged between 39.0% and 90.9% for the garlic samples extracted with deionized water. The developed method is simple, precise, accurate, reliable, and time -effective for the determination of OSCs. Additionally, the green profile of the developed method was investigated by using AGREEprep software and the greenness score recorded as 0.65, indicating that the method developed is environmentally friendly. | en |
| dc.description.sponsorship | Yildiz Technical University Scientific Research Projects Committee [TSA- 2021-4114] | |
| dc.description.uri | https://doi.org/10.55730/1300-0527.3658 | |
| dc.identifier.doi | 10.55730/1300-0527.3658 | |
| dc.identifier.issn | 1300-0527 | |
| dc.identifier.issue | 2 | |
| dc.identifier.pubmed | 39050505 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14981/67877 | |
| dc.identifier.volume | 48 | |
| dc.identifier.wos | 001222836700011 | |
| dc.language.iso | eng | |
| dc.publisher | Tubitak Scientific & Technological Research Council Turkey | |
| dc.relation.ispartof | TURKISH JOURNAL OF CHEMISTRY | |
| dc.rights | openAccess | |
| dc.subject | Organosulfur compounds | |
| dc.subject | high-performance liquid chromatography | |
| dc.subject | garlic | |
| dc.subject | extraction | |
| dc.subject | COLON-CANCER CELLS | |
| dc.subject | DIALLYL TRISULFIDE | |
| dc.subject | SULFIDE | |
| dc.subject | VALIDATION | |
| dc.subject | DISULFIDE | |
| dc.subject | APOPTOSIS | |
| dc.subject | Chemistry | |
| dc.subject | Engineering | |
| dc.title | Sensitive and accurate determination of oil-soluble and water-soluble organosulfur compounds in garlic matrix using reversed phase-high performance liquid chromatography | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| local.import.source | WOS |