Yayın:
Sensitive and accurate determination of oil-soluble and water-soluble organosulfur compounds in garlic matrix using reversed phase-high performance liquid chromatography

dc.contributor.authorPolat Korkunc, Ummugulsum
dc.contributor.authorZaman, Buse Tugba
dc.contributor.authorBakirdere, Sezgin
dc.contributor.authorKarakus, Emine
dc.date.accessioned2026-06-27T15:05:51Z
dc.date.issued2024
dc.description.abstractGarlic is in the family Liliaceae and has many different constituents such as organic sulfur compounds, amino acids, carbohydrates, minerals, andvitamins. In this work, a simple, sensitive, and accurate analytical method was developed for the determination of selected organosulfur compounds (OSCs) in garlic bulbs using reversed phase -high performance liquid chromatography (RP-HPLC). Oil -soluble and water-soluble OSCs were extracted from the garlic samples via acetonitrile and deionized water, respectively. The OSCs were separated on a Phenomenex C18 (250 mm, 4 mm, 5mm) column and the monitoring was performed with a UV detector at nm. An isocratic mobile phase comprising of 0.10 M trifluoroacetic acid (TFA) in 85% acetonitrile (ACN) and 0.10 M TFA in distilled water (DW) (90: 10% v/v) was used to elute the analytes. Under optimum experimental conditions, the limits of detection (LOD) the analytes were calculated in the range of 0.09 to 0.17 mg/kg. For the garlic sample extracts analyzed under optimal instrumental conditions, DAS (diallyl sulfide), DADS (diallyl disulfide), and DATS (diallyl trisulfide) were detected in the ranges of 8.0 to 32.5 kg, 20.4 to 67.3 mg/kg, and 60.7 to 356.6 mg/kg, respectively. Spiked recovery experiments were conducted on the garlic samples confirm the method's applicability and accuracy. The recovery results ranged between 39.0% and 90.9% for the garlic samples extracted with deionized water. The developed method is simple, precise, accurate, reliable, and time -effective for the determination of OSCs. Additionally, the green profile of the developed method was investigated by using AGREEprep software and the greenness score recorded as 0.65, indicating that the method developed is environmentally friendly.en
dc.description.sponsorshipYildiz Technical University Scientific Research Projects Committee [TSA- 2021-4114]
dc.description.urihttps://doi.org/10.55730/1300-0527.3658
dc.identifier.doi10.55730/1300-0527.3658
dc.identifier.issn1300-0527
dc.identifier.issue2
dc.identifier.pubmed39050505
dc.identifier.urihttps://hdl.handle.net/20.500.14981/67877
dc.identifier.volume48
dc.identifier.wos001222836700011
dc.language.isoeng
dc.publisherTubitak Scientific & Technological Research Council Turkey
dc.relation.ispartofTURKISH JOURNAL OF CHEMISTRY
dc.rightsopenAccess
dc.subjectOrganosulfur compounds
dc.subjecthigh-performance liquid chromatography
dc.subjectgarlic
dc.subjectextraction
dc.subjectCOLON-CANCER CELLS
dc.subjectDIALLYL TRISULFIDE
dc.subjectSULFIDE
dc.subjectVALIDATION
dc.subjectDISULFIDE
dc.subjectAPOPTOSIS
dc.subjectChemistry
dc.subjectEngineering
dc.titleSensitive and accurate determination of oil-soluble and water-soluble organosulfur compounds in garlic matrix using reversed phase-high performance liquid chromatography
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar