Yayın:
A Novel Liquid-Liquid Extraction for the Determination of Sertraline in Tap Water and Waste Water at Trace Levels by GC-MS

dc.contributor.authorKocoglu, Elif Seda
dc.contributor.authorBakirdere, Sezgin
dc.contributor.authorKeyf, Seyfullah
dc.date.accessioned2026-06-27T14:06:29Z
dc.date.issued2017
dc.description.abstractA simple, green and fast analytical method was developed for the determination of sertraline in tap and waste water samples at trace levels by using supportive liquid-liquid extraction with gas chromatography-mass spectrometry. Different parameters affecting extraction efficiency such as types and volumes of extraction and supporter solvents, extraction period, salt type and amount were optimized to get lower detection limits. Ethyl acetate was selected as optimum extraction solvent. In order to improve the precision, anthracene-D10 was used as an internal standard. The calibration plot of sertraline was linear from 1.0 to 1000 ng/mL with a correlation coefficient of 0.999. The limit of detection value under the optimum conditions was found to be 0.43 ng/mL. In real sample measurements, spiking experiments were performed to check the reliability of the method for these matrices. The spiking experiments yielded satisfactory recoveries of 91.19 +/- 2.48%, 90.48 +/- 5.19% and 95.46 +/- 6.56% for 100, 250 and 500 ng/mL sertraline for tap water, and 85.80 +/- 2.15% and 92.43 +/- 4.02% for 250 and 500 ng/mL sertraline for waste water.en
dc.description.urihttps://doi.org/10.1007/s00128-017-2118-2
dc.identifier.doi10.1007/s00128-017-2118-2
dc.identifier.eissn1432-0800
dc.identifier.endpage359
dc.identifier.issn0007-4861
dc.identifier.issue3
dc.identifier.pubmed28555336
dc.identifier.startpage354
dc.identifier.urihttps://hdl.handle.net/20.500.14981/57093
dc.identifier.volume99
dc.identifier.wos000408269400012
dc.language.isoeng
dc.publisherSPRINGER
dc.relation.ispartofBULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY
dc.subjectSertraline
dc.subjectSupportive liquid-liquid extraction
dc.subjectGC-MS
dc.subjectInternal standard
dc.subjectSOLID-PHASE EXTRACTION
dc.subjectCHROMATOGRAPHY-MASS SPECTROMETRY
dc.subjectSEROTONIN REUPTAKE INHIBITORS
dc.subjectPERSONAL CARE PRODUCTS
dc.subjectACTIVE METABOLITES
dc.subjectSENSITIVE DETERMINATION
dc.subjectHUMAN SERUM
dc.subjectPHARMACEUTICALS
dc.subjectANTIDEPRESSANTS
dc.subjectMICROEXTRACTION
dc.subjectEnvironmental Sciences & Ecology
dc.subjectToxicology
dc.titleA Novel Liquid-Liquid Extraction for the Determination of Sertraline in Tap Water and Waste Water at Trace Levels by GC-MS
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar