Yayın:
Experimental Study on the Specific Heat Capacity Measurement of Water-Based Al2O3-Cu Hybrid Nanofluid by using Differential Thermal Analysis Method

dc.contributor.authorColak, Andac Batur
dc.contributor.authorYildiz, Oguzhan
dc.contributor.authorBayrak, Mustafa
dc.contributor.authorCelen, Ali
dc.contributor.authorDalkilic, Ahmet Selim
dc.contributor.authorWongwises, Somchai
dc.date.accessioned2026-06-27T14:34:45Z
dc.date.issued2020
dc.description.abstractBackground: Researchers working in the field of nanofluid have done many studies on the thermophysical properties of nanofluids. Among these studies, the number of studies on specific heat is rather limited. In the study of the heat transfer performance of nanofluids, it is essential to raise the number of specific heat studies, whose subject is one of the important thermophysical properties. Objective: The authors aimed to measure the specific heat values of Al2O3/water, Cu/water nanofluids and Al2O3-Cu/water hybrid nanofluids using the DTA procedure, and compare the results with those frequently used in the literature. In addition, this study focuses on the effect of temperature and volume concentration on specific heat. Methods: The two-step method was tried to have nanofluids. The pure water selected as the base fluid was mixed with the Al2O3 and Cu nanoparticles and Arabic Gum as the surfactant, firstly mixed in the magnetic stirrer for half an hour. It was then homogenized for 6 hours in the ultrasonic homogenizer. Results: After the experiments, the specific heat of nanofluids and hybrid nanofluid were compared and the temperature and volume concentration of specific heat were investigated. Then, the experimental results obtained for all three fluids were compared with the two frequently used correlations in the literature. Conclusion: Specific heat capacity increased with increasing temperature, and decreased with increasing volume concentration for three tested nanofluids. Cu/water has the lowest specific heat capacity among all tested fluids. Experimental specific heat capacity measurement results are compared by using the models developed by Pak and Cho and Xuan and Roetzel. According to experimental results, these correlations can predict experimental results within the range of +/- 1%.en
dc.description.sponsorshipNigde Omer Halisdemir University Scientific Research Projects Coordination Department [FEB2018/17-BAGEP]
dc.description.urihttps://doi.org/10.2174/1573413715666191118105331
dc.identifier.doi10.2174/1573413715666191118105331
dc.identifier.eissn1875-6786
dc.identifier.endpage928
dc.identifier.issn1573-4137
dc.identifier.issue6
dc.identifier.startpage912
dc.identifier.urihttps://hdl.handle.net/20.500.14981/62304
dc.identifier.volume16
dc.identifier.wos000612155000006
dc.language.isoeng
dc.publisherBENTHAM SCIENCE PUBL LTD
dc.relation.ispartofCURRENT NANOSCIENCE
dc.subjectHybrid nanofluid
dc.subjectspecific heat capacity
dc.subjectdifferential thermal analysis
dc.subjectmagnetic stirrer
dc.subjectultrasonic homogenizer
dc.subjectheat transfer
dc.subjectnanoparticle
dc.subjectTHERMOPHYSICAL PROPERTIES
dc.subjectPHYSICAL PROPERTIES
dc.subjectAL2O3-WATER NANOFLUIDS
dc.subjectCONDUCTIVITY
dc.subjectVISCOSITY
dc.subjectNANOPARTICLES
dc.subjectDISSIPATION
dc.subjectSTABILITY
dc.subjectMWCNTS
dc.subjectFLOW
dc.subjectBiotechnology & Applied Microbiology
dc.subjectScience & Technology - Other Topics
dc.subjectMaterials Science
dc.titleExperimental Study on the Specific Heat Capacity Measurement of Water-Based Al2O3-Cu Hybrid Nanofluid by using Differential Thermal Analysis Method
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar