Yayın:
Correlations for evaporation heat transfer coefficient and two-phase friction factor for R-134a flowing through horizontal corrugated tubes

dc.contributor.authorLaohalertdecha, Suriyan
dc.contributor.authorDalkilic, Ahmet Selim
dc.contributor.authorWongwises, Somchai
dc.contributor.institutionauthorDALKILIÇ, Ahmet Selim
dc.date.accessioned2026-06-27T13:14:55Z
dc.date.issued2011
dc.description.abstractCorrelations for the evaporation heat transfer coefficient and two-phase friction factor of R-134a flowing through horizontal corrugated tubes are proposed. In the present study, the test section is a horizontal counter-flow concentric tube-in-tube heat exchanger with R-134a flowing in the inner tube and hot water flowing in the annulus. Smooth tube and corrugated tubes with inner diameters of 8.7 mm and lengths of 2000 mm are used as the inner tube. The corrugation pitches are 5.08, 6.35, and 8.46 mm and the corrugation depths are 1, 1.25, and 1.5 mm, respectively. The outer tube is made from smooth copper tube with an inner diameter of 21.2 mm. The correlations presented are formed by using approximately 200 data points for five different corrugated tube geometries and are then proposed in terms of Nusselt number, equivalent Reynolds number, Prandtl number, corrugation pitch and depth, and inside diameter. (C) 2011 Elsevier Ltd. All rights reserved.en
dc.description.sponsorshipThailand Research Fund
dc.description.sponsorshipOffice of the Higher Education Commission
dc.description.sponsorshipNational Research University
dc.description.urihttps://doi.org/10.1016/j.icheatmasstransfer.2011.08.014
dc.identifier.doi10.1016/j.icheatmasstransfer.2011.08.014
dc.identifier.eissn1879-0178
dc.identifier.endpage1413
dc.identifier.issn0735-1933
dc.identifier.issue10
dc.identifier.startpage1406
dc.identifier.urihttps://hdl.handle.net/20.500.14981/51017
dc.identifier.volume38
dc.identifier.wos000298219100016
dc.language.isoeng
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD
dc.relation.ispartofINTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER
dc.subjectTwo-phase friction factor
dc.subjectHeat transfer
dc.subjectTemperature
dc.subjectR-134a
dc.subjectCorrugated tube
dc.subjectTWISTED TAPE INSERTS
dc.subjectTURBULENT-FLOW
dc.subjectPRESSURE-DROP
dc.subjectCONDENSATION
dc.subjectENHANCEMENT
dc.subjectCOMBINATION
dc.subjectPREDICTION
dc.subjectANNULUS
dc.subjectCOIL
dc.subjectThermodynamics
dc.subjectMechanics
dc.titleCorrelations for evaporation heat transfer coefficient and two-phase friction factor for R-134a flowing through horizontal corrugated tubes
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar