Yayın:
Optimization of T-shape slotted quartz tube with exit holes-atom trap-flame atomic absorption spectrophotometry system for the accurate and sensitive determination of tellurium in tap water

dc.contributor.authorSahin, Ipek
dc.contributor.authorDurak, Busra Yilmaz
dc.contributor.authorSagsoz, Oguzhan
dc.contributor.authorBuyukpinar, Cagdas
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T14:27:43Z
dc.date.issued2020
dc.description.abstractTellurium has been widely used in industrial processes and daily life products, and can cause serious health problems upon exposure. Therefore, determination of tellurium in real-life samples is very crucial. In this study, an accurate, environmentally friendly, and inexpensive analytical method was developed to determine trace levels of tellurium in water samples. To lower the detection limits, system parameters including flame type, acetylene flow rate, slotted quartz tube (T-SQT) height, and trapping period were optimized. Under the optimum conditions, the limit of detection (LOD) and quantification (LOQ) were calculated as 14.1 ng/mL and 47.1 ng/mL, respectively. For recovery studies, the optimized T-SQT-AT-FAAS method was applied to tap water samples to determine trace levels of tellurium and recovery results were found between 91.1 and 111.3%. Relative standard deviation value (%RSD) of the developed method was found to be less than 5.0% even for the lowest concentration in calibration plot, specifying good accuracy and high applicability of the method for water samples. Graphical abstract .en
dc.description.urihttps://doi.org/10.1007/s10661-019-8043-6
dc.identifier.doi10.1007/s10661-019-8043-6
dc.identifier.eissn1573-2959
dc.identifier.issn0167-6369
dc.identifier.issue1
dc.identifier.pubmed31865447
dc.identifier.urihttps://hdl.handle.net/20.500.14981/60874
dc.identifier.volume192
dc.identifier.wos000503823400001
dc.language.isoeng
dc.publisherSPRINGER
dc.relation.ispartofENVIRONMENTAL MONITORING AND ASSESSMENT
dc.subjectTellurium
dc.subjectAtom trap
dc.subjectSlotted quartz tube
dc.subjectHydrogen
dc.subjectFlame atomic absorption spectrophotometry
dc.subjectTap water
dc.subjectSPECTROMETRY
dc.subjectEnvironmental Sciences & Ecology
dc.titleOptimization of T-shape slotted quartz tube with exit holes-atom trap-flame atomic absorption spectrophotometry system for the accurate and sensitive determination of tellurium in tap water
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar