Yayın:
Determination of copper in traditional coffee pot water samples by flame atomic absorption spectrometry and matrix matching calibration strategy after switchable solvent based liquid-phase microextraction

dc.contributor.authorErcan, Maral Selin Findikoglu
dc.contributor.authorAyyildiz, Merve Firat
dc.contributor.authorChormey, Dotse Selali
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T14:32:17Z
dc.date.issued2021
dc.description.abstractTraditional copper coffee pots are widely used in these modern times and daily consumption of coffee brewed in overused/old pots increases the risk of copper ingestion. This study employed a green switchable solvent-based liquid-phase microextraction (SS-LPME) method to isolate and preconcentrate copper from water boiled in coffee pots. Copper was determined by a flame atomic absorption spectrometry (FAAS) system coupled with a slotted quartz tube (SQT). 1,5-Diphenylcarbazone was added to aqueous samples to form a complex with copper before the extraction step. Box-Behnken experimental design was applied to select optimum conditions of the extraction method that were used to validate the analytical method. The limits of quantification and detection of the optimized SS-LPME-SQT-FAAS method were determined as 9.1 and 2.7 mu g/L, respectively. Water samples boiled in traditional coffee pots were spiked at different concentrations and analyzed to ascertain the method's accuracy and applicability to real samples. Satisfactory recovery results obtained in the range of 92-107% established good accuracy, and percent relative standard deviations lower than 8.0% also proved high precision.en
dc.description.urihttps://doi.org/10.1007/s10661-020-08729-w
dc.identifier.doi10.1007/s10661-020-08729-w
dc.identifier.eissn1573-2959
dc.identifier.issn0167-6369
dc.identifier.issue1
dc.identifier.pubmed33305346
dc.identifier.urihttps://hdl.handle.net/20.500.14981/61793
dc.identifier.volume193
dc.identifier.wos000600216200002
dc.language.isoeng
dc.publisherSPRINGER
dc.relation.ispartofENVIRONMENTAL MONITORING AND ASSESSMENT
dc.subjectCopper
dc.subjectFAAS
dc.subjectSS-LPME
dc.subjectSQT
dc.subjectExperimental design
dc.subjectSPECTROPHOTOMETRIC DETERMINATION
dc.subjectFAAS DETERMINATION
dc.subjectIONIC LIQUID
dc.subjectPRECONCENTRATION
dc.subjectEXTRACTION
dc.subjectFOOD
dc.subjectCHROMIUM
dc.subjectALUMINUM
dc.subjectVANADIUM
dc.subjectNICKEL
dc.subjectEnvironmental Sciences & Ecology
dc.titleDetermination of copper in traditional coffee pot water samples by flame atomic absorption spectrometry and matrix matching calibration strategy after switchable solvent based liquid-phase microextraction
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar