Yayın:
Vortex-assisted switchable liquid-liquid microextraction for the preconcentration of cadmium in environmental samples prior to its determination with flame atomic absorption spectrometry

dc.contributor.authorFirat, Merve
dc.contributor.authorBodur, Suleyman
dc.contributor.authorTisli, Busra
dc.contributor.authorOzlu, Cansu
dc.contributor.authorChormey, Dotse Selali
dc.contributor.authorTurak, Fatma
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T14:13:55Z
dc.date.issued2018
dc.description.abstractIn this study, a switchable solvent was used to preconcentrate trace amounts of Cd from aqueous solution for its determination by flame atomic absorption spectrometry (FAAS). Protonation of N,N-dimethylbenzylamine by dry ice (solid CO2) made it water soluble, and addition of sodium hydroxide converted it back to its original nonionic state for phase separation and subsequent extraction of Cd. A slotted quartz tube (SQT) was attached to the flame burner head to increase the residence time of Cd atoms in the light path. Under the optimum conditions, limits of detection and quantification were determined as 0.7 and 2.6 mu g L-1, respectively. Low relative standard deviations calculated from seven replicate measurements of the lowest concentration indicated high precision. Accuracy of the developed method was checked by using a standard reference material (SRM 1633c). Spiked recovery tests were also performed on lake water and wastewater samples at different concentrations to check the applicability of the developed method, and the results obtained (90-103%) established high recovery.en
dc.description.urihttps://doi.org/10.1007/s10661-018-6786-0
dc.identifier.doi10.1007/s10661-018-6786-0
dc.identifier.eissn1573-2959
dc.identifier.issn0167-6369
dc.identifier.issue7
dc.identifier.pubmed29892908
dc.identifier.urihttps://hdl.handle.net/20.500.14981/58222
dc.identifier.volume190
dc.identifier.wos000435077600005
dc.language.isoeng
dc.publisherSPRINGER
dc.relation.ispartofENVIRONMENTAL MONITORING AND ASSESSMENT
dc.subjectCd
dc.subjectFAAS
dc.subjectSQT
dc.subjectSwitchable solvent extraction
dc.subjectPHASE MICROEXTRACTION
dc.subjectTRACE LEVELS
dc.subjectEXTRACTION
dc.subjectNICKEL
dc.subjectWATER
dc.subjectLEAD
dc.subjectSEA
dc.subjectEnvironmental Sciences & Ecology
dc.titleVortex-assisted switchable liquid-liquid microextraction for the preconcentration of cadmium in environmental samples prior to its determination with flame atomic absorption spectrometry
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar