Yayın:
AIR-SIDE PERFORMANCE OF A MICRO-CHANNEL HEAT EXCHANGER IN WET SURFACE CONDITIONS

dc.contributor.authorSrisomba, Raviwat
dc.contributor.authorAsirvatham, Lazarus Godson
dc.contributor.authorMahian, Omid
dc.contributor.authorDalkilic, Ahmet Selim
dc.contributor.authorAwad, Mohamed M.
dc.contributor.authorWongwises, Somchai
dc.date.accessioned2026-06-27T13:59:30Z
dc.date.issued2017
dc.description.abstractThe effects of operating conditions on the air-side heat transfer, and pressure drop of a micro-channel heat exchanger under wet surface conditions were studied experimentally. The test section was an aluminum micro-channel heat exchanger, consisting of a multi-louvered fin and multi-port mini-channels. Experiments were conducted to study the effects of inlet relative humidity, air frontal velocity, air inlet temperature, and refrigerant temperature on air-side performance. The experimental data were analyzed using the mean enthalpy difference method. The test run was performed at relative air humidity's ranging between 45% and 80%; air inlet temperature ranges of 27, 30, and 33 degrees C, refrigerant-saturated temperatures ranging from 18 to 22 degrees C, and Reynolds numbers between 128 and 166. The results show that the inlet relative humidity, air inlet temperature, and the refrigerant temperature had significant effects on heat transfer performance and air-side pressure drop. The heat transfer coefficient and pressure drop for the micro-channel heat exchanger under wet surface conditions are proposed in terms of the Colburn factor and Fanning factor.en
dc.description.sponsorshipResearch Chair Grant National Science and Technology Development Agency (NSTDA)
dc.description.sponsorshipThailand Research Fund (TRF)
dc.description.sponsorshipNational Research University Project (NRU)
dc.description.sponsorshipKing Mongkut's University of Technology Thonburi through the KMUTT 55th Anniversary Commemorative Fund
dc.description.urihttps://doi.org/10.2298/tsci150906227s
dc.identifier.doi10.2298/tsci150906227s
dc.identifier.eissn2334-7163
dc.identifier.endpage385
dc.identifier.issn0354-9836
dc.identifier.issue1
dc.identifier.startpage375
dc.identifier.urihttps://hdl.handle.net/20.500.14981/56332
dc.identifier.volume21
dc.identifier.wos000396378300036
dc.language.isoeng
dc.publisherVINCA INST NUCLEAR SCI
dc.relation.ispartofTHERMAL SCIENCE
dc.rightsopenAccess
dc.subjectautomotive air-conditioning
dc.subjectheat transfer coefficient
dc.subjectmicro-channel heat exchanger
dc.subjectpressure drop
dc.subjectR-134a
dc.subjectTUBE
dc.subjectPUMP
dc.subjectThermodynamics
dc.titleAIR-SIDE PERFORMANCE OF A MICRO-CHANNEL HEAT EXCHANGER IN WET SURFACE CONDITIONS
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar