Yayın:
Maximum Permissible Integration Capacity of Renewable DG Units Based on System Loads

dc.contributor.authorDogansahin, Kadir
dc.contributor.authorKekezoglu, Bedri
dc.contributor.authorYumurtaci, Recep
dc.contributor.authorErdinc, Ozan
dc.contributor.authorCatalao, Joao P. S.
dc.date.accessioned2026-06-27T14:15:57Z
dc.date.issued2018
dc.description.abstractIncreasing demand for electricity, as well as rising environmental and economic concerns have resulted in renewable energy sources being a center of attraction. Integration of these renewable energy resources into power systems is usually achieved through distributed generation (DG) techniques, and the number of such applications increases daily. As conventional power systems do not have an infrastructure that is compatible with these energy sources and generation systems, such integration applications may cause various problems in power systems. Therefore, planning is an essential part of DG integration, especially for power systems with intermittent renewable energy sources with the objective of minimizing problems and maximizing benefits. In this study, a mathematical model is proposed to calculate the maximum permissible DG integration capacity without causing overvoltage problems in the power systems. In the proposed mathematical model, both the minimum loading condition and maximum generation condition are taken into consideration. In order to prove the effectiveness and the consistency of the proposed mathematical model, it is applied to a test system with different case studies, and the results are compared with the results obtained from other models in the literature.en
dc.description.sponsorshipFEDER funds through COMPETE
dc.description.sponsorshipPortuguese funds through FCT [SAICT-PAC/0004/2015-POCI-01-0145-FEDER-016434, POCI-01-0145-FEDER-006961, UID/EEA/50014/2013, UID/CEC/50021/2013, UID/EMS/00151/2013, SFRH/BPD/103744/2014]
dc.description.sponsorshipEU [309048]
dc.description.urihttps://doi.org/10.3390/en11010255
dc.identifier.doi10.3390/en11010255
dc.identifier.eissn1996-1073
dc.identifier.issue1
dc.identifier.urihttps://hdl.handle.net/20.500.14981/58624
dc.identifier.volume11
dc.identifier.wos000424397600254
dc.language.isoeng
dc.publisherMDPI
dc.relation.ispartofENERGIES
dc.rightsopenAccess
dc.subjectrenewable energy
dc.subjectdistributed generation
dc.subjectmaximum permissible capacity
dc.subjectPOWER DISTRIBUTION NETWORKS
dc.subjectVOLTAGE STABILITY
dc.subjectPLACEMENT
dc.subjectLOSSES
dc.subjectIMPACT
dc.subjectMINIMIZATION
dc.subjectRELIABILITY
dc.subjectSTRATEGIES
dc.subjectEnergy & Fuels
dc.titleMaximum Permissible Integration Capacity of Renewable DG Units Based on System Loads
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar