Yayın:
Determination of Cobalt in Tap Water by Deep Eutectic Solvent-Dithizone Assisted Liquid Phase Microextraction (LPME) Preconcentration with Flame Atomic Absorption Spectrometry (FAAS)

dc.contributor.authorAgbulak, Asli
dc.contributor.authorKilinc, Yagmur
dc.contributor.authorZaman, Buse Tugba
dc.contributor.authorGover, Tugce
dc.contributor.authorAtakol, Melike
dc.contributor.authorTurak, Fatma
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T15:14:51Z
dc.date.issued2026
dc.description.abstractThis study aimed to develop an analytical method for preparing samples to preconcentrate cobalt from water in advance for determination using flame atomic absorption spectrometry (FAAS). The aforementioned outcome was attained through the complexing of cobalt ions with dithizone (Co-DTZ) and subsequently extracting the resulting complex from aqueous solution using a deep eutectic solvent (DES). The DES/DTZ probe was used as a complexing and extracting agent in the developed liquid phase microextraction (LPME) procedure. The most suitable experimental conditions were determined for the highest extraction efficiency. Consequently, 8.0 mL of standard/sample solution was adjusted to pH 6.0 using 1.0 mL of phthalate buffer. 250 mu L of the DES/DTZ probe (10 mL DES: 5.0 mg DTZ) was added to the aqueous solution to extract cobalt with the best efficiency. The DES/DTZ-LPME-FAAS system achieved a detection limit of 9.6 mu g/L with a wide linear working range between 30 and 500 mu g/L by applying the optimum procedure. The relative standard deviation of the proposed method was 6.9% for a 30 mu g/L cobalt standard. Spike recovery experiments were conducted with tap water to evaluate the accuracy and feasibility of the developed method. By performing matrix matching, the results demonstrated good recoveries from 90% to 112%.en
dc.description.urihttps://doi.org/10.1080/00032719.2025.2466764
dc.identifier.doi10.1080/00032719.2025.2466764
dc.identifier.eissn1532-236X
dc.identifier.endpage68
dc.identifier.issn0003-2719
dc.identifier.issue1
dc.identifier.startpage57
dc.identifier.urihttps://hdl.handle.net/20.500.14981/69445
dc.identifier.volume59
dc.identifier.wos001424285900001
dc.language.isoeng
dc.publisherTAYLOR & FRANCIS INC
dc.relation.ispartofANALYTICAL LETTERS
dc.rightsopenAccess
dc.subjectCobalt
dc.subjectdeep eutective solvent
dc.subjectdithizone
dc.subjectflame atomic absorption spectrometry (FAAS)
dc.subjectliquid phase microextraction (LPME)
dc.subjectSAMPLES
dc.subjectNICKEL
dc.subjectIONS
dc.subjectChemistry
dc.titleDetermination of Cobalt in Tap Water by Deep Eutectic Solvent-Dithizone Assisted Liquid Phase Microextraction (LPME) Preconcentration with Flame Atomic Absorption Spectrometry (FAAS)
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar