Yayın: α-Amylase assay with starch-iodine-sodium fluorescein-based fluorometric method in human serum samples
| dc.contributor.author | Zafer, Julide Buse | |
| dc.contributor.author | Dede, Sureyya | |
| dc.contributor.author | Karakus, Emine | |
| dc.date.accessioned | 2026-06-27T14:30:52Z | |
| dc.date.issued | 2021 | |
| dc.description.abstract | A new fluorometric method was developed for the determination of alpha-amylase activity in human serum samples. Firstly, a saturated starch-iodine complex (SI) was prepared. The SI complex was combined with sodium fluorescein to form a starch-iodine-sodium fluorescein complex (SIF). As the SIF complex decomposes with the alpha-amylase enzymatic hydrolysis of starch, the intensity of its fluorescence emission increases. The alpha-amylase activity is determined using the increased fluorescence emission intensity following hydrolysis of the SIF complex by alpha-amylase. The optimum pH, optimum buffer concentration, optimum temperature, and interference effect were identified for the developed fluorometric measurement method. Under the optimum conditions, a linear calibration curve was obtained between 0.18 and 9.00 U/L for alpha-amylase. The alpha-amylase activity in the human serum sample was also determined by our prepared measurement system and compared with the result from a medical center. Both methods are in good agreement with each other. Because this newly developed fluorometric method for alpha-amylase activity in serum samples is inexpensive, easy to use, and carried out to detect a very low amount of human serum alpha-amylase with sensitivity, it can be proposed this method for alpha-amylase activity assay in all other biological samples. | en |
| dc.description.sponsorship | Turkey Scientific and Technological Research Institution [2210-C] | |
| dc.description.uri | https://doi.org/10.1080/10826068.2020.1843177 | |
| dc.identifier.doi | 10.1080/10826068.2020.1843177 | |
| dc.identifier.eissn | 1532-2297 | |
| dc.identifier.endpage | 606 | |
| dc.identifier.issn | 1082-6068 | |
| dc.identifier.issue | 6 | |
| dc.identifier.pubmed | 33427021 | |
| dc.identifier.startpage | 599 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14981/61499 | |
| dc.identifier.volume | 51 | |
| dc.identifier.wos | 000606704900001 | |
| dc.language.iso | eng | |
| dc.publisher | TAYLOR & FRANCIS INC | |
| dc.relation.ispartof | PREPARATIVE BIOCHEMISTRY & BIOTECHNOLOGY | |
| dc.subject | alpha-amylase | |
| dc.subject | sodium fluorescein | |
| dc.subject | starch | |
| dc.subject | iodine | |
| dc.subject | fluorometry | |
| dc.subject | Biochemistry & Molecular Biology | |
| dc.subject | Biotechnology & Applied Microbiology | |
| dc.title | α-Amylase assay with starch-iodine-sodium fluorescein-based fluorometric method in human serum samples | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| local.import.source | WOS |