Yayın:
α-Amylase assay with starch-iodine-sodium fluorescein-based fluorometric method in human serum samples

dc.contributor.authorZafer, Julide Buse
dc.contributor.authorDede, Sureyya
dc.contributor.authorKarakus, Emine
dc.date.accessioned2026-06-27T14:30:52Z
dc.date.issued2021
dc.description.abstractA new fluorometric method was developed for the determination of alpha-amylase activity in human serum samples. Firstly, a saturated starch-iodine complex (SI) was prepared. The SI complex was combined with sodium fluorescein to form a starch-iodine-sodium fluorescein complex (SIF). As the SIF complex decomposes with the alpha-amylase enzymatic hydrolysis of starch, the intensity of its fluorescence emission increases. The alpha-amylase activity is determined using the increased fluorescence emission intensity following hydrolysis of the SIF complex by alpha-amylase. The optimum pH, optimum buffer concentration, optimum temperature, and interference effect were identified for the developed fluorometric measurement method. Under the optimum conditions, a linear calibration curve was obtained between 0.18 and 9.00 U/L for alpha-amylase. The alpha-amylase activity in the human serum sample was also determined by our prepared measurement system and compared with the result from a medical center. Both methods are in good agreement with each other. Because this newly developed fluorometric method for alpha-amylase activity in serum samples is inexpensive, easy to use, and carried out to detect a very low amount of human serum alpha-amylase with sensitivity, it can be proposed this method for alpha-amylase activity assay in all other biological samples.en
dc.description.sponsorshipTurkey Scientific and Technological Research Institution [2210-C]
dc.description.urihttps://doi.org/10.1080/10826068.2020.1843177
dc.identifier.doi10.1080/10826068.2020.1843177
dc.identifier.eissn1532-2297
dc.identifier.endpage606
dc.identifier.issn1082-6068
dc.identifier.issue6
dc.identifier.pubmed33427021
dc.identifier.startpage599
dc.identifier.urihttps://hdl.handle.net/20.500.14981/61499
dc.identifier.volume51
dc.identifier.wos000606704900001
dc.language.isoeng
dc.publisherTAYLOR & FRANCIS INC
dc.relation.ispartofPREPARATIVE BIOCHEMISTRY & BIOTECHNOLOGY
dc.subjectalpha-amylase
dc.subjectsodium fluorescein
dc.subjectstarch
dc.subjectiodine
dc.subjectfluorometry
dc.subjectBiochemistry & Molecular Biology
dc.subjectBiotechnology & Applied Microbiology
dc.titleα-Amylase assay with starch-iodine-sodium fluorescein-based fluorometric method in human serum samples