Yayın:
Investigation of radiation protective features of azadispiro derivatives and their genotoxic potential with Ames/Salmonella test system

Yükleniyor...
Küçük Resim

Tarih

Kurum Yazarları

Danışman

item.page.editor

Editör

Bölüm / Program

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

TAYLOR & FRANCIS LTD

DOI

10.1080/09553002.2022.2087930

Türü

View PlumX Details

Araştırma Projeleri

Akademik Birimler

Dergi Sayısı

Özet

Purpose Five different types of synthesized azadispiro derivatives have been analyzed for radiation absorption capacity and determined their potential to be exploited as substances for a drug to be developed against radiation has been investigated. Material and methods Fast neutron attenuation parameters like the effective mean free path, half-value layer (HVL), removal cross-sections, and neutron transmission number were found with the Monte Carlo simulation Geometry And Tracking (GEANT4) code. Gamma radiation absorption parameters, such as effective atom number (Z(eff)), mean free path (MFP), mass attenuation coefficient (MAC), and half-value layer (HVL) were theoretically determined with WinXCom software. Besides, the exposure build-up factor (EBF) was calculated by using GP fitting parameters. Neutron absorption dose rate was experimentally calculated with Am-241-Be fast neutron source which has 4.5 MeV of energy, 74 GBq activity, and portative BF3 neutron detector. Ames/Salmonella test systems were used for the genotoxic potentials of the azadispiro derivatives Results and conclusions Experimental and theoretical results were checked with paraffin and High-Density Polyethylene. The results showed that Azadispiro derivatives have neutron radiation absorption capability close to paraffin and High-Density Polyethylene. The gamma radiation absorption properties for azadispiro derivatives have been investigated, and it has been observed that these materials can absorb gamma radiation. Ames/Salmonella assay was used to examine whether the derivatives had a genotoxic effect probability or not. The results showed that these derivatives were genotoxic and safe at test doses (up to 5 mM). Consequently, it has been understood that these azadispiro derivatives can be used as active and genotoxic safety ingredients in the production of a protective drug against both neutrons and gamma rays.

Tanım

Dergi veya Seri

INTERNATIONAL JOURNAL OF RADIATION BIOLOGY

ISSN

0955-3002

ISBN

Alıntı

Koleksiyonlar

Onay

Gözden geçir

Tamamlayıcı Bilgiler

Referans Gösteren

Related Patent

Related Goal

0

Views

0

Downloads