Yayın:
EXPERIMENTAL DETERMINATION OF THE WETTED AREA OF A FALLING FILM ON THE OUTSIDE OF HORIZONTAL TUBES USING IMAGE PROCESSING AND HEAT TRANSFER ANALYSIS

dc.contributor.authorOnan, Cenk
dc.contributor.authorOzkan, Derya B.
dc.date.accessioned2026-06-27T14:01:42Z
dc.date.issued2017
dc.description.abstractFalling film is observed in closed-type cooling towers, evaporative condensers, and in absorption cooling. In this study, the aim was to increase the amount of evaporating water on the tube surface during the falling of the film. To increase the area of wetness, grooves of different shapes were used, which were placed longitudinally or helically on horizontal tubes. The groove geometries were triangular, trapezoidal, round, and square. In the experiments, the area of wetness was measured by generating falling film-type flow on horizontal tubes with these four different groove geometries. The falling film-type flow was generated using dyed water to measure the area of wetness. Photographs were taken using a high-speed camera to determine the area of wetness in the tubes. The photographs were processed using MATLAB, and it was concluded that the tube of helical trapezoidal geometry had the maximum rate of wet area of 74% and that the tube of longitudinal trapezoidal groove geometry had the minimum rate of 46%. Afterwards, the amount of evaporating water, heat convection coefficients, and Nusselt number values were determined. The results indicated that as the temperature of the feeding water increased, the amount of evaporating water also increased. The Nusselt correlation was observed at different temperatures of feeding water between 30 degrees C and 40 degrees C and depending on the Re-w and Re-a of the falling film. It was determined that while Re-w was between 100 and 350, the observed heat convection coefficient was between 15 and 55 W/m(2) K for the simultaneous heat and mass transfer.en
dc.description.urihttps://doi.org/10.1615/heattransres.2016010684
dc.identifier.doi10.1615/heattransres.2016010684
dc.identifier.eissn2162-6561
dc.identifier.endpage548
dc.identifier.issn1064-2285
dc.identifier.issue6
dc.identifier.startpage529
dc.identifier.urihttps://hdl.handle.net/20.500.14981/56495
dc.identifier.volume48
dc.identifier.wos000397625200003
dc.language.isoeng
dc.publisherBEGELL HOUSE INC
dc.relation.ispartofHEAT TRANSFER RESEARCH
dc.subjectheat transfer
dc.subjecthorizontal tube
dc.subjectfalling film
dc.subjectimage processing
dc.subjectgroove
dc.subjectFLOW
dc.subjectEVAPORATION
dc.subjectThermodynamics
dc.titleEXPERIMENTAL DETERMINATION OF THE WETTED AREA OF A FALLING FILM ON THE OUTSIDE OF HORIZONTAL TUBES USING IMAGE PROCESSING AND HEAT TRANSFER ANALYSIS
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar