Yayın:
Islanding Detection in Microgrids Using Harmonic Signatures

dc.contributor.authorMerino, Julia
dc.contributor.authorMendoza-Araya, Patricio
dc.contributor.authorVenkataramanan, Giri
dc.contributor.authorBaysal, Mustafa
dc.contributor.institutionauthorBAYSAL, Mustafa
dc.date.accessioned2026-06-27T13:43:51Z
dc.date.issued2015
dc.description.abstractIn recent years, there has been a growing interest in incorporating microgrids in electrical power networks. This is due to various advantages they present, particularly the possibility of working in either autonomous mode or grid connected, which makes them highly versatile structures for incorporating intermittent generation and energy storage. However, they pose safety issues in being able to support a local island in case of utility disconnection. Thus, in the event of an unintentional island situation, they should be able to detect the loss of mains and disconnect for self-protection and safety reasons. Most of the anti-islanding schemes are implemented within control of single generation devices, such as dc-ac inverters used with solar electric systems being incompatible with the concept of microgrids due to the variety and multiplicity of sources within the microgrid. In this paper, a passive islanding detection method based on the change of the 5th harmonic voltage magnitude at the point of common coupling between grid-connected and islanded modes of operation is presented. Hardware test results from the application of this approach to a laboratory scale microgrid are shown. The experimental results demonstrate the validity of the proposed method, in meeting the requirements of IEEE 1547 standards.en
dc.description.sponsorshipWisconsin Electric Machines and Power Electronics Consortium (WEMPEC)
dc.description.urihttps://doi.org/10.1109/tpwrd.2014.2383412
dc.identifier.doi10.1109/tpwrd.2014.2383412
dc.identifier.eissn1937-4208
dc.identifier.endpage2109
dc.identifier.issn0885-8977
dc.identifier.issue5
dc.identifier.startpage2102
dc.identifier.urihttps://hdl.handle.net/20.500.14981/54578
dc.identifier.volume30
dc.identifier.wos000361911200005
dc.language.isoeng
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
dc.relation.ispartofIEEE TRANSACTIONS ON POWER DELIVERY
dc.rightsopenAccess
dc.subjectHarmonic signature
dc.subjectislanding detection method
dc.subjectmicrogrid
dc.subjectVOLTAGES
dc.subjectCURRENTS
dc.subjectPLL
dc.subjectEngineering
dc.titleIslanding Detection in Microgrids Using Harmonic Signatures
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar