Na2Si3O7/BaO composites for the gamma-ray shielding in medical applications: Experimental, MCNP5, and WinXCom studies

dc.contributor.authorCaglar, Mustafa
dc.contributor.authorKayacik, Hande
dc.contributor.authorKarabul, Yasar
dc.contributor.authorKilic, Mehmet
dc.contributor.authorOzdemir, Zeynep Guven
dc.contributor.authorIcelli, Orhan
dc.date.accessioned2026-06-27T14:18:51Z
dc.date.issued2019
dc.description.abstractThe role of BaO in the glassy structured Na2Si3O7 was investigated in the context of gamma radiations shielding parameters in the study. The mass attenuation coefficient, half layer value, and mean free path of the Na2Si3O7/BaO composites were calculated experimentally for the photons with the energies of 81 keV and 356 key emitted from 133Ba point radioactive source. The same parameters were also calculated by Monte Carlo N-particle simulation (MCNP5) for the gamma photons which are emitted from Ba-133, (241)AM (TC)-T-99m, (LU)-L-177, Ir-192, and Cs-137 radioactive sources. The effective atomic number and effective electron density were determined by WinXCom software. Additionally, the scattered gamma photon intensity of the composites was realized for the energy of 364 key and compared with the most utilized radiation shielding material lead. It was concluded that the composite having the highest BaO additive exhibits the best gamma photon absorption ability at all energies investigated.en
dc.description.sponsorshipYildiz Technical University Scientific Research Projects Coordination Department [2015-01-01-KAP06]
dc.description.urihttps://doi.org/10.1016/j.pnucene.2019.103119
dc.identifier.doi10.1016/j.pnucene.2019.103119
dc.identifier.issn0149-1970
dc.identifier.urihttps://hdl.handle.net/20.500.14981/59144
dc.identifier.volume117
dc.identifier.wos000489190600035
dc.language.isoeng
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD
dc.relation.ispartofPROGRESS IN NUCLEAR ENERGY
dc.subjectSodium silicate
dc.subjectBarium oxide
dc.subjectComposite
dc.subjectGamma-ray shielding
dc.subjectMCNP
dc.subjectWinXCom
dc.subjectEFFECTIVE ATOMIC NUMBERS
dc.subjectX-RAY
dc.subjectATTENUATION COEFFICIENTS
dc.subjectELECTRON-DENSITIES
dc.subjectGLASSES
dc.subjectPARAMETERS
dc.subjectPROGRAM
dc.subjectLEAD
dc.subjectNuclear Science & Technology
dc.titleNa2Si3O7/BaO composites for the gamma-ray shielding in medical applications: Experimental, MCNP5, and WinXCom studies
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS