Yayın:
Effects of Bed Height and Particle Size on Drying of a Turkish Lignite

Yükleniyor...
Küçük Resim

Tarih

Kurum Yazarları

Danışman

item.page.editor

Editör

Bölüm / Program

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

TAYLOR & FRANCIS INC

DOI

10.1080/19392699.2015.1009051

Türü

View PlumX Details

Araştırma Projeleri

Akademik Birimler

Dergi Sayısı

Özet

Drying of coarse lignite particles, because of high inherent moisture content, is very important for the lignite user. An effective drying process is necessary to utilize coarse lignite particles effectively. Fixed-bed drying experiments were carried out for a Turkish lignite (Konya-Ilgin). Effects of bed height and particle size were investigated. Drying experiments were carried out at 80, 130, and 150 mm bed heights and 20, 35, and 50 mm particle sizes. It was found that increasing the bed height increased the drying time and decreased the drying rate, and particles of larger sizes have lower drying rates and higher drying times. Additionally, it was also found that Konya-Ilgin lignite does not show a constant drying rate and has a long falling drying rate. As a result of this study, drying characteristics of Konya-Ilgin lignite were presented for different drying conditions.