Yayın:
Development of an Accurate and Sensitive Analytical Method for the Determination of Cadmium at Trace Levels Using Dispersive Liquid-Liquid Microextraction Based on the Solidification of Floating Organic Drops Combined with Slotted Quartz Tube Flame Atomic Absorption Spectrometry

dc.contributor.authorAydin, Ilgin
dc.contributor.authorChormey, Dotse Selali
dc.contributor.authorBudak, Turkan
dc.contributor.authorFirat, Merve
dc.contributor.authorTurak, Fatma
dc.contributor.authorBakirdere, Sezgin
dc.date.accessioned2026-06-27T14:13:15Z
dc.date.issued2018
dc.description.abstractA dispersive liquid liquid microextraction (DLLME) technique based on a solidification-of-floating-organic-drop (SFOD) procedure was developed for the determination of trace amounts of cadmium (Cd) by using a flame atomic absorption spectrometer (FAAS) fitted with a slotted quartz tube (SQT). The extraction of Cd was achieved by forming a complex with diphenylcarbazone. Parameters affecting the formation of complex and extraction outputs were carefully optimized to obtain high-absorbance signals to achieve lower LODs. An SQT was fitted on top of the flame burner head to further enhance the absorbance of the signals recorded by the FAAS. Coupling the DLLME-SFOD procedure with SQT-FAAS produced an enhancement factor of about 183. The LOD of the method was 0.23 mu g/L with an RSD of 3.8%. Matrix-matching was used to overcome any low recovery results obtained with tap water and municipal wastewater.en
dc.description.urihttps://doi.org/10.5740/jaoacint.17-0131
dc.identifier.doi10.5740/jaoacint.17-0131
dc.identifier.eissn1944-7922
dc.identifier.endpage847
dc.identifier.issn1060-3271
dc.identifier.issue3
dc.identifier.pubmed28903806
dc.identifier.startpage843
dc.identifier.urihttps://hdl.handle.net/20.500.14981/58092
dc.identifier.volume101
dc.identifier.wos000431471000030
dc.language.isoeng
dc.publisherAOAC INT
dc.relation.ispartofJOURNAL OF AOAC INTERNATIONAL
dc.subjectSOLID-PHASE EXTRACTION
dc.subjectCLOUD POINT EXTRACTION
dc.subjectMASS SPECTROMETRY
dc.subjectWATER SAMPLES
dc.subjectICP-MS
dc.subjectLEAD
dc.subjectPRECONCENTRATION
dc.subjectGENERATION
dc.subjectCARBON
dc.subjectCOPPER
dc.subjectChemistry
dc.subjectFood Science & Technology
dc.titleDevelopment of an Accurate and Sensitive Analytical Method for the Determination of Cadmium at Trace Levels Using Dispersive Liquid-Liquid Microextraction Based on the Solidification of Floating Organic Drops Combined with Slotted Quartz Tube Flame Atomic Absorption Spectrometry
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar