Effects of various drilling parameters on bone during implantology: An in vitro experimental study

dc.contributor.authorKaraca, Faruk
dc.contributor.authorAksakal, Bunyamin
dc.date.accessioned2026-06-27T13:29:32Z
dc.date.issued2013
dc.description.abstractDue to temperature increase during bone drilling, bone necrosis is likely to occur. To minimize bone tissue damage during drilling, a detailed in vitro experimental study by using fresh calf cortical bones has been performed with various combined drilling parameters, such as: drilling environment, drill diameter, drill speed, drill force, feed-rate and drill coating. Bone temperatures at the drilling sites were recorded with high accuracy using multi-thermocouples mounted around the tibial diaphyseal cortex. It was shown that temperatures increased with increased drill speeds. It also decreased with a higher feed-rate and drill force. It was also observed that TiBN coated drills caused higher temperatures in the bone than the uncoated drills and the temperatures increased with larger drill diameters. Although the influence of Simulated Body Fluid (SBF) on rising temperatures during drilling was higher for the TiBN coated drills, it was observed that these drills caused more damage to the bone structure. In order to minimize or avoid bone defects and necrosis, orthopaedic surgeons should consider the optimum drilling parameters.en
dc.description.urihttps://doi.org/10.5277/abb130404
dc.identifier.doi10.5277/abb130404
dc.identifier.endpage32
dc.identifier.issn1509-409X
dc.identifier.issue4
dc.identifier.pubmed24479623
dc.identifier.startpage25
dc.identifier.urihttps://hdl.handle.net/20.500.14981/53162
dc.identifier.volume15
dc.identifier.wos000332507000004
dc.language.isoeng
dc.publisherWROCLAW UNIV TECHNOLOGY, FAC COMPUTER SCIENCE & MANAGEMENT
dc.relation.ispartofACTA OF BIOENGINEERING AND BIOMECHANICS
dc.subjectorthopaedics
dc.subjectbone drilling
dc.subjecttemperature
dc.subjectbone necrosis
dc.subjectTEMPERATURE-CHANGE
dc.subjectHEAT-PRODUCTION
dc.subjectRIB BONE
dc.subjectEFFICIENCY
dc.subjectBiophysics
dc.subjectEngineering
dc.titleEffects of various drilling parameters on bone during implantology: An in vitro experimental study