Yayın: Effect of bulk modulus on performance of a hydrostatic transmission control system
| dc.contributor.author | Akkaya, Ali Volkan | |
| dc.date.accessioned | 2026-06-27T13:01:49Z | |
| dc.date.issued | 2006 | |
| dc.description.abstract | In this paper, we examine the performance of PID (proportional integral derivative) and fuzzy controllers on the angular velocity of a hydrostatic transmission system by means of Matlab-Simulink. A very novel aspect is that it includes the analysis of the effect of bulk modulus on system control. Simulation results demonstrates that bulk modulus should be considered as a variable parameter to obtain a more realistic model. Additionally, a PID controller is insufficient in presence of variable bulk modulus, whereas a fuzzy controller provides robust angular velocity control. | en |
| dc.description.uri | https://doi.org/10.1007/bf02715913 | |
| dc.identifier.doi | 10.1007/bf02715913 | |
| dc.identifier.eissn | 0973-7677 | |
| dc.identifier.endpage | 556 | |
| dc.identifier.issn | 0256-2499 | |
| dc.identifier.startpage | 543 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14981/49215 | |
| dc.identifier.volume | 31 | |
| dc.identifier.wos | 000242279000005 | |
| dc.language.iso | eng | |
| dc.publisher | SPRINGER INDIA | |
| dc.relation.ispartof | SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES | |
| dc.subject | hydrostatic transmission | |
| dc.subject | bulk modulus | |
| dc.subject | PID (proportional integral derivative) | |
| dc.subject | fuzzy controller | |
| dc.subject | Engineering | |
| dc.title | Effect of bulk modulus on performance of a hydrostatic transmission control system | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| local.import.source | WOS |