Yayın:
Numerical investigation of heat transfer and pressure drop in enhanced tubes

dc.contributor.authorAgra, Ozden
dc.contributor.authorDemir, Hakan
dc.contributor.authorAtayilmaz, S. Ozgur
dc.contributor.authorKantas, Fatih
dc.contributor.authorDalkilic, Ahmet Selim
dc.contributor.institutionauthorDALKILIÇ, Ahmet Selim
dc.date.accessioned2026-06-27T13:15:47Z
dc.date.issued2011
dc.description.abstractThis study investigates passive heat transfer enhancement techniques to determine the distribution of temperature and static pressure in test tubes, the friction factor, the heat flux, the temperature difference between the inlet and outlet fluid temperatures, the pressure drop penalty and the numerical convective heat transfer coefficient, and then compares the results to the experimental data of Zdaniuk et al. It predicts the single-phase friction factors for the smooth and enhanced tubes by means of the empirical correlations of Blasius and Zdaniuk et al. This study performed calculations on a smooth tube and two helically finned tubes with different geometric parameters also used in the analyses of Zdaniuk et al. It also performed calculations on two corrugated tubes in the simulation study. In Zdaniuk et al.'s experimental setup, the horizontal test section was a 2.74 m long countercurrent flow double tube heat exchanger with the fluid of water flowing in the inner copper tube (15.57-15.64 mm i.d.) and cooling water flowing in the annulus (31.75 mm i.d.). Their test runs were performed at a temperature around 20 degrees C for cold water flowing in the annulus while Reynolds numbers ranged from 12,000 to 57,000 for the water flowing in the inner tube. A single-phase numerical model having three-dimensional equations is employed with either constant or temperature dependent properties to study the hydrodynamics and thermal behaviors of the flow. The temperature contours are presented for inlet, outlet and fully developed regions of the tube. The variations of the fluid temperature and static pressure along tube length are shown in the paper. The results obtained from a numerical analysis for the helically tubes were validated by various friction factor correlations, such as those found by Blasius and Zdaniuk et al. Then, numerical results were obtained for the two corrugated tubes as a simulation study. The present study found that the average deviation is less than 5% for the friction factors obtained by the Fluent CFD program while Blasius's correlation has the average deviation of less than 10%. The corrugated tubes have a higher heat transfer coefficient than smooth tubes but a lower coefficient than helically finned tubes. The paper also investigates the pressure drop penalty for the heat transfer enhancement. (C) 2011 Elsevier Ltd. All rights reserved.en
dc.description.urihttps://doi.org/10.1016/j.icheatmasstransfer.2011.07.013
dc.identifier.doi10.1016/j.icheatmasstransfer.2011.07.013
dc.identifier.endpage1391
dc.identifier.issn0735-1933
dc.identifier.issue10
dc.identifier.startpage1384
dc.identifier.urihttps://hdl.handle.net/20.500.14981/51186
dc.identifier.volume38
dc.identifier.wos000298219100013
dc.language.isoeng
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD
dc.relation.ispartofINTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER
dc.subjectHeat transfer coefficient
dc.subjectPressure drop
dc.subjectFriction
dc.subjectCorrugated tube
dc.subjectHelically finned tube
dc.subjectCFD
dc.subjectSPIRALLY CORRUGATED TUBES
dc.subjectHELICALLY-FINNED TUBES
dc.subjectTWISTED TAPE INSERTS
dc.subjectTURBULENT-FLOW
dc.subjectFLUID-FLOW
dc.subjectTRANSFER COEFFICIENTS
dc.subjectFRICTION FACTORS
dc.subjectCOMBINATION
dc.subjectPREDICTION
dc.subjectEXCHANGER
dc.subjectThermodynamics
dc.subjectMechanics
dc.titleNumerical investigation of heat transfer and pressure drop in enhanced tubes
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS