Yayın:
Novel Micro Flow Injection Analysis System for the Potentiometric Determination of Tetraborate Ions in Environmental Samples

dc.contributor.authorTopcu, Cihan
dc.contributor.authorIsildak, Ibrahim
dc.date.accessioned2026-06-27T14:25:17Z
dc.date.issued2021
dc.description.abstractA novel micro flow injection analysis system was developed for the potentiometric determination of tetraborate ions in environmental samples. The flow system was created by embedding the previously developed tetraborate selective sensor into a home-made micro-flow cell with dead volume. The flow conditions of the system was optimized. The potentiometric performance of the tetraborate selective sensor was characterized using the optimized flow conditions. The sensor showed a supra-Nernstian slope of 45.7 +/- 1.3 mV/decade of activity in the tetraborate concentration range from 1.0 x 10(-4)to 1.0 x 10(-1 )mol L(-1)with a correlation coefficient equal to 0.9994. The detection limit of the tetraborate sensor was observed to be 9.6 x 10(-5 )mol L-1. The sensor exhibited a rapid response time, good selectivity, and favorable repeatability toward tetraborate ions. Additionally, the selective tetraborate sensor displayed good operational stability and its average lifetime was determined to be 14 weeks in the flow injection analysis system. The sensor was also successfully applied for the direct potentiometric determination of tetraborate ions in environmental samples using the optimized micro flow injection analysis system.en
dc.description.urihttps://doi.org/10.1080/00032719.2020.1786105
dc.identifier.doi10.1080/00032719.2020.1786105
dc.identifier.eissn1532-236X
dc.identifier.endpage866
dc.identifier.issn0003-2719
dc.identifier.issue5
dc.identifier.startpage854
dc.identifier.urihttps://hdl.handle.net/20.500.14981/60430
dc.identifier.volume54
dc.identifier.wos000549641700001
dc.language.isoeng
dc.publisherTAYLOR & FRANCIS INC
dc.relation.ispartofANALYTICAL LETTERS
dc.subjectBoron monitoring
dc.subjectenvironmental analysis
dc.subjectflow injection analysis
dc.subjectpotentiometric determination
dc.subjecttetraborate selective sensor
dc.subjectCARBON-PASTE ELECTRODE
dc.subjectSELECTIVE ELECTRODE
dc.subjectSPECTROPHOTOMETRIC DETERMINATION
dc.subjectBORON DETERMINATION
dc.subjectCOPPER(II)
dc.subjectBORATE
dc.subjectBATCH
dc.subjectWATER
dc.subjectHYDROCHLORIDE
dc.subjectSENSOR
dc.subjectChemistry
dc.titleNovel Micro Flow Injection Analysis System for the Potentiometric Determination of Tetraborate Ions in Environmental Samples
dc.typeArticle
dspace.entity.typePublication
local.import.sourceWOS

Dosyalar

Koleksiyonlar